• Ann Work Expo Health · Jul 2021

    Intubator Performance and Contamination with the Use of Barrier Enclosure Devices: Results from a Simulated COVID-19 Resuscitation.

    • Maxim Ben-Yakov, Courtney Price, Alia Dharamsi, Davy Tawadrous, and Joseph M Choi.
    • Division of Emergency Medicine, Faculty of Medicine, University of Toronto, Faculty of Medicine, University of Toronto, Toronto, ON, Canada.
    • Ann Work Expo Health. 2021 Jul 3; 65 (6): 732-737.

    IntroductionMedical institutions are using barrier enclosure devices during intubation procedures and other aerosol-generating medical procedures without evidence of their effectiveness or usability, potentially compromising patient care, and provider safety. Our objective was to determine the degree of protection offered by these devices and explore other usability factors for two popular barrier systems.MethodsA simulated trial comparing an intubation box, a frame and plastic tarp system, and unprotected intubation was performed in an academic emergency department. Ten emergency physicians were recruited to participate. Our primary outcome was the degree of contamination from secretions measured by average surface area exposed to phosphorescent material. Secondary outcomes included: laryngoscopy time and time to barrier application, unsuccessful intubation attempts, and usability ratings for each system. Descriptive statistics were reported for all variables of interest and a linear mixed model was used to analyze contamination and laryngoscopy time. Usability was captured through electronic questionnaires using a five-point Likert scale.ResultsContamination was more prevalent with the box, compared to the frame and tarp, and no device, however, this did not achieve statistical significance (13.2% versus 8.1% versus 12.2%, P = 0.17). A barrier system delayed intubation when compared to using no system (no system = 24.4 s [95% CI 17.3-27.5], frame = 54.4 s [95% CI 13.8-95.0], box = 33.8 s [95% CI 21.4-46.1], P = 0.02). In assessing usability, 30% of users preferred the use of a box barrier, 40% of users preferred the frame, and 30% would not use either in future intubation.ConclusionsCompared to no barrier protection, an intubation box enclosure offers limited additional protection. A frame and tarp system reduces exposure at the expense of visibility and operator comfort. Finally, barrier systems do not appear to have a clinically significant impact on airway management.© The Author(s) 2021. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.