• Z Kardiol · Nov 1994

    [Quantitative evaluation of myocardial perfusion with ultrafast magnetic resonance tomography].

    • T Machnig, A Koroneos, G Engels, K Bachmann, C Simm, N Wilke, J Ellermann, J Zhang, X Ya, and H Merkel.
    • II. Med. Klinik, Universität Erlangen/Nürnberg.
    • Z Kardiol. 1994 Nov 1; 83 (11): 840-50.

    AbstractWith the advent of ultrafast Magnetic Resonance Imaging (MRI), it is now possible to produce images with high temporal resolution. This gives the opportunity to record the passage of the paramagnetic contrast material Gadolinium-DTPA through the tissue of the heart muscle, yielding information on regional myocardial perfusion. We assessed the accuracy of MRI to detect and quantify reductions in coronary flow secondary to stenosis in dogs and patients. Regional blood flow was measured in dogs by left atrial injection of microspheres labeled with different radioactive isotopes. Signal intensity (SI) curves were generated in regions of interest over the myocardium and the cavum of the left ventricle. A newly developed two-compartment model based on the indicator-dilution method was used for interpretation of the SI-curves. In an optimization process the free parameters of the model equation were fitted to the measured SI-curves. The following flow parameters were determined: model parameter Q*, time to peak intensity (T), maximum signal intensity (SImax) and mean transit time (MTT) as calculated from a gamma variate fit. Absolute blood flow values were calculated for the parameters MTT and Q* assuming that the intravascular volume represents 10% of the total myocardial tissue volume. Measurements were performed on a 1.5 T Magnetom SP (Siemens AG, Erlangen) using a Turbo Flash sequence (TR = 6.5 ms, TE = 3 ms, TI = 100 ms, Flip Winkel = 9 degrees). Endsystolic images (voxel size = 1.8, 2.7, 15 mm3) were taken with an 18-cm Helmholtz surface coil in the short-axis view. A Gd-DTPA bolus (0.05 mmol/kg) was injected into the left atrium of 3 anesthetized closed-chest dogs. From the myocardial SI-curves the different parameters of myocardial perfusion were compared with flow assessed by microsphere injection over a wide range of myocardial blood flows (from 0.04 ml/min/g to 7.6 ml/min/g). A third-order polynominal fit showed a good correlation for the parameter Q* and MTT, whereas T and SImax were found to have a poor correlation. The linear regression analysis for a limited range of < 2 ml/min/g showed a superior estimation of myocardial perfusion for the parameter Q* than MTT. Blood flow > 2 ml/min/g was significantly underestimated by the MRT-measurements, but the parameter Q* showed the smallest amount of the divergent changes.(ABSTRACT TRUNCATED AT 400 WORDS)

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?

    User can't be blank.

    Content can't be blank.

    Content is too short (minimum is 15 characters).

    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…