• J Vasc Interv Radiol · Mar 2019

    Polyethylene Glycol Epirubicin-Loaded Transcatheter Arterial Chemoembolization Procedures Utilizing a Combined Approach with 100 and 200 μm Microspheres: A Promising Alternative to Current Standards.

    • Pierleone Lucatelli, Renato Argirò, Gianluca De Rubeis, Bianca Rocco, Stefano Ginanni Corradini, Mario Corona, Pier Giorgio Nardis, Luca Saba, Gianluca Mennini, Francesco Fiorentino, Alessandro Corsi, Carlo Catalano, and Mario Bezzi.
    • Vascular and Interventional Radiology Unit, Department of Diagnostic Service, Sapienza University of Rome, Rome, Italy. Electronic address: pierleone.lucatelli@gmail.com.
    • J Vasc Interv Radiol. 2019 Mar 1; 30 (3): 305-313.

    PurposeTo report clinical effectiveness, toxicity profile, and prognostic factors of combined 100 μm ± 25 and 200 μm ± 50 epirubicin-loaded polyethylene glycol (PEG) microsphere drug-eluting embolic transcatheter arterial chemoembolization protocol in patients with hepatocellular carcinoma.Materials And MethodsIn this prospective, single-center, single-arm study with 18 months of follow-up, 36 consecutive patients (mean age 69.9 y ± 10.8; 26 men, 10 women; 54 naïve lesions) were treated. Embolization was initiated with 100 μm ± 25 microspheres, and if stasis (10 heart beats) was not achieved, 200 μm ± 50 microspheres were administered. Each syringe (2 mL) of PEG microsphere was loaded with 50 mg of epirubicin. Results were evaluated using Modified Response Evaluation Criteria In Solid Tumors with multidetector computed tomography/magnetic resonance imaging at 1, 3-6, 9-12, and 15-18 months. Toxicity profile was assessed by laboratory testing before and after the procedure. Complications were recorded. Postembolization syndrome (PES) was defined as onset of fever/nausea/pain after the procedure. Patient/lesion characteristics and treatment results were correlated with predicted outcome using regression analysis. Child-Pugh score was A in 86.1% of patients (31/36) and B in 13.9% (5/36).ResultsIn 10 of 21 lesions, < 2 cm in diameter (47.5%) stasis was achieved with 100 μm ± 25 microspheres only, whereas all other lesions required adjunctive treatment with 200 μm ± 50 microspheres. Reported adverse events were grade 1 acute liver bile duct injury (3/39 cases, 7.7%) and PES (grade 2; 3/39 cases, 7.7%). Complete response (CR) at 1, 3-6, 9-12, and 15-18 months was 61.1%, 65.5%, 63.63%, and 62.5%. Objective response (CR + partial response) at 1, 3-6, 9-12, and 15-18 months was 83.3%, 65.85%, 63.63%, and 62.5%. No single factor (laboratory testing, etiology, patient status, hepatic status, tumor characteristics, administration protocol) predicted outcomes except for albumin level at baseline for CR (P < .05, odds ratio = 1.09).ConclusionsThe combined microsphere sizing strategy was technically feasible and yielded promising results in terms of effectiveness and toxicity.Copyright © 2018 SIR. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…