-
Investigative radiology · Jun 2007
Comparative StudyIntraindividual comparison of MR-renal perfusion imaging at 1.5 T and 3.0 T.
- Henrik J Michaely, Harald Kramer, Niels Oesingmann, Klaus-Peter Lodemann, Karl Miserock, Maximilian F Reiser, and Stefan O Schoenberg.
- Department of Clinical Radiology, University Hospitals - Grosshadern, Ludwig-Maximilians-University Munich, Germany. Henrik.Michaelry@med.uni-muenchen.de
- Invest Radiol. 2007 Jun 1; 42 (6): 406-11.
PurposeThe purpose of this study was to intraindividually compare fast gradient-echo semiquantitative renal perfusion measurements at 1.5 Tesla (T) and 3.0 Tesla.Materials And MethodsFifteen healthy male volunteers underwent renal perfusion measurements at 1.5 T and 3.0 T after the bolus injection of 7 mL of Gd-BOPTA. At both field strengths a Saturation-Recovery-fast gradient echo sequence (SR-TurboFLASH) with a temporal resolution of 4 (1.5 T) and 5 (3.0 T) simultaneously acquired slices per second was used. At 3.0 T, a parallel-imaging factor 2 was applied. For postprocessing, semiquantitative perfusion parameters including mean transit time (MTT), time to peak (TTP), and maximal signal intensity (SMax) were determined. The signal-to-noise ratios (SNR) of kidneys and aorta were determined precontrast and after enhancement. The image quality was rated by 2 radiologists. After Bonferroni correction paired t-tests were performed for statistical analysis.ResultsAll measurements were successfully performed. At 3.0 T, a significant 63% increase in the baseline SNR (P = 0.00005) of the kidneys was found, the peak SNR was also increased though not statistically significant. Because of the higher SNR, the SMax was also significantly (P = 0.005) increased from 406 A.U. to 522 A.U., whereas MTT and TTP were not significantly changed. The image quality was rated very good to good for the 3.0 T images but only good to moderate at 1.5 T.ConclusionRenal perfusion measurements at 3.0 T are feasible and directly benefit from the inherently higher SNR at 3.0 T. The higher SNR also translates into an increased SMax, whereas MTT and TTP are independent of the field strength.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.