Observational Study
Accuracy of intracoronary ECG parameters for myocardial ischemia detection.
- Marius Reto Bigler, Patrick Zimmermann, Athanasios Papadis, and Christian Seiler.
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Switzerland.
- J Electrocardiol. 2021 Jan 1; 64: 50-57.
IntroductionThe electrocardiogram (ECG) is a valuable diagnostic tool for the diagnosis of myocardial ischemia during acute coronary syndrome. Aside from the commonly used ST-segment shift indicative of ischemia, several other ECG parameters are pathophysiologically reasonable. Thus, the goal of this study was to assess the accuracy of different ischemia parameters as obtained by the highly susceptible intracoronary ECG (icECG).MethodThis was a retrospective observational study in 100 patients with chronic coronary syndrome. From each patient, a non-ischemic as well as ischemic icECG at the end of a one-minute proximal coronary balloon occlusion was available, and analysed twice by three different physicians, as well as once together for consensual results. The evaluated parameters were icECG ST-segment shift (mV), ST-integral (mV*sec), T-wave-integral (mV*sec), T-peak (mV), T-peak-to-end time (TPE; msec) and QTc-time (msec).ResultsAll six icECG parameters showed significant differences between the non-ischemic and the ischemic recording. Using the icECG recording during coronary patency or occlusion as criterion for absent or present myocardial ischemia, ROC-analysis of icECG ST-segment shift showed an area under the curve (AUC) of 0.963 ± 0.029 (p < 0.0001). AUC for ST-integral was 0.899 ± 0.044 (p < 0.0001), for T-wave integral 0.791 ± 0.059 (p < 0.0001), for T-peak 0.811 ± 0.057 (p < 0.0001), for TPE 0.667 ± 0.068 (p < 0.0001), and for QTc-time 0.770 ± 0.061 (p < 0.0001). The best cut-off point for the detection of ischemia by icECG ST-segment shift was 0.365 mV (sensitivity 90%, specificity 95%).ConclusionWhen tested in a setting with artificially induced absolute myocardial ischemia, icECG ST-segment shift at a threshold of 0.365 mV most accurately distinguishes between absent and present ischemia.Copyright © 2020 The Author(s). Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.