• J Comput Assist Tomogr · Jan 2007

    Female breast radiation exposure during thorax multidetector computed tomography and the effectiveness of bismuth breast shield to reduce breast radiation dose.

    • Mehmet Halit Yilmaz, Sait Albayram, Doğan Yaşar, Harun Ozer, Ibrahim Adaletli, Doğan Selçuk, Canan Akman, and Ayça Altuğ.
    • Department of Radiology, Cerrahpasa Medical Faculty, Istanbul University, Turkey. drmhyilmaz@yahoo.com
    • J Comput Assist Tomogr. 2007 Jan 1; 31 (1): 138-42.

    ObjectiveThe purpose of our study was to determine the breast radiation dose when performing routine thoracic multidetector computed tomography (MDCT). We also evaluated dose reduction and the effect on image quality of using a bismuth breast shield when performing thoracic MDCT.Material And MethodsThe dose reduction achievable by shielding the adult (18 years or older) female breasts was studied in 50 women who underwent routine thoracic MDCT. All examinations were performed with a 16-MDCT scanner (Sensation Cardiac 16; Siemens Medical Solutions). To compare the shielded/unshielded breast dose, the examination was performed with (right breast) and without (left breast) breast shielding in all patients. With this technique, the superficial breast doses were calculated. To determine the average glandular breast radiation dose, we imaged an anthropomorphic dosimetric phantom into which calibrated dosimeters were placed to measure the dose to breast. The phantom was imaged using the same protocol. Radiation doses to the breasts with and without the breast shielding were measured and compared using the Student t test.ResultsIn the qualitative evaluation of the MDCT scans, all were considered to be of diagnostic quality. We did not see any differences in quality between the shielded and unshielded lung. The mean radiation doses to the breasts with the shield and to those without the shield were 8.6 +/- 2.33 versus 14.46 +/- 3.94 mGy, respectively. The breast shield enabled a 40.53% decrease in radiation dose to the breast. The difference between the dose received by the breasts with and that received by the breasts without bismuth shielding was significant, with a P value of less than 0.001.ConclusionsBismuth in-plane shielding for routine thoracic MDCT decreased radiation dose to the breast without qualitative changes in image quality. The other radiosensitive superficial organs (eg, testes and thyroid gland) specifically must be protected with shielding.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…