• IEEE Trans Med Imaging · Aug 2004

    Comparative Study Clinical Trial

    Adaptive averaging for improved SNR in real-time coronary artery MRI.

    • Marshall S Sussman, Normand Robert, and Graham A Wright.
    • Department of Medical Biophysics, Sunnybrook Health Science Centre, University of Toronto, Toronto, ON M5G 2N2, Canada. marshall.sussman@utoronto.ca
    • IEEE Trans Med Imaging. 2004 Aug 1; 23 (8): 1034-45.

    AbstractA technique has been developed for combining a series of low signal-to-noise ratio (SNR) real-time magnetic resonance (MR) images to produce composite images with high SNR and minimal artifact in the presence of motion. The main challenge is identifying a set of real-time images with sufficiently small systematic differences to avoid introducing significant artifact into the composite image. To accomplish this task, one must: 1) identify images identical within the limits of noise; 2) detect systematic errors within such images with sufficient sensitivity. These steps are achieved by evaluating the correlation coefficient (CC) between regions in prospective images and a template containing the anatomy of interest. Images identical within noise are selected by comparing the measured CC values to the theoretical distribution expected due to noise. Sensitivity for systematic error depends on the SNR of the CC (=SNR(CCmax)), which in turn depends on the noise, and the template size and structure. By varying the template size, SNR(CCmax) may be altered. Experiments on phantoms and coronary artery images demonstrate that the SNR(CCmax) necessary to avoid introducing significant artifact varies with the target composite SNR. The future potential of this technique is demonstrated on high-resolution (approximately 0.9 mm), reduced field-of-view real-time coronary images.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…