• Radiother Oncol · Jul 2008

    Comparative Study

    Persistently better treatment planning results of intensity-modulated (IMRT) over conformal radiotherapy (3D-CRT) in prostate cancer patients with significant variation of clinical target volume and/or organs-at-risk.

    • Pascal Fenoglietto, Benoit Laliberte, Ali Allaw, Norbert Ailleres, Katia Idri, Meng Huor Hay, Carmen Llacer Moscardo, Sophie Gourgou, Jean-Bernard Dubois, and David Azria.
    • Département d'Oncologie Radiothérapie, CRLC Val d'Aurelle-Paul Lamarque, Montpellier, France. pfenoglietto@valdorel.fnclcc.fr
    • Radiother Oncol. 2008 Jul 1; 88 (1): 77-87.

    PurposeTo compare the dose coverage of planning and clinical target volume (PTV, CTV), and organs-at-risk (OAR) between intensity-modulated (3D-IMRT) and conventional conformal radiotherapy (3D-CRT) before and after internal organ variation in prostate cancer.Methods And MaterialsWe selected 10 patients with clinically significant interfraction volume changes. Patients were treated with 3D-IMRT to 80 Gy (minimum PTV dose of 76 Gy, excluding rectum). Fictitious, equivalent 3D-CRT plans (80 Gy at isocenter, with 95% isodose (76 Gy) coverage of PTV, with rectal blocking above 76 Gy) were generated using the same planning CT data set ("CT planning"). The plans were then also applied to a verification CT scan ("CT verify") obtained at a different moment. PTV, CTV, and OAR dose coverage were compared using non-parametric tests statistics for V95, V90 (% of the volume receiving 95 or 90% of the dose) and D50 (dose to 50% of the volume).ResultsMean V95 of the PTV for "CT planning" was 94.3% (range, 88-99) vs 89.1% (range, 84-94.5) for 3D-IMRT and 3D-CRT (p=0.005), respectively. Mean V95 of the CTV for "CT verify" was 97% for both 3D-IMRT and 3D-CRT. Mean D50 of the rectum for "CT planning" was 26.8 Gy (range, 22-35) vs 43.5 Gy (range, 33.5-50.5) for 3D-IMRT and 3D-CRT (p=0.0002), respectively. For "CT verify", this D50 was 31.1 Gy (range, 16.5-44) vs 44.2 Gy (range, 34-55) for 3D-IMRT and 3D-CRT (p=0.006), respectively. V95 of the rectum was 0% for both plans for "CT planning", and 2.3% (3D-IMRT) vs 2.1% (3D-CRT) for "CT verify" (p=non-sig.).ConclusionDose coverage of the PTV and OAR was better with 3D-IMRT for each patient and remained so after internal volume changes.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…