• Catheter Cardiovasc Interv · Oct 2017

    Transcatheter closure of hemodynamic significant patent ductus arteriosus in 32 premature infants by amplatzer ductal occluder additional size-ADOIIAS.

    • Patrice Morville and Ahmad Akhavi.
    • Pediatric and Pediatric Cardiology, Head of NICU, American Memorial Hospital, Reims, France.
    • Catheter Cardiovasc Interv. 2017 Oct 1; 90 (4): 612-617.

    ObjectivesThe advent of Amplatzer Duct Occluder II additional Size (ADOIIAS) provided the potential to close hemodynamic significant patent ductus arteriosus (HSPDA) and to analyze the feasibility, safety and efficacy of the device.BackgroundTreatment of a patent ductus arteriosus (PDA) in very premature neonates is still a dilemma for the neonatalogist who has to consider its significance and has to choose among different treatment options. Because surgical ligation and medical therapy both have their drawbacks, interventional catheterization might provide an alternative means of closing HSPDA.Material And MethodsBetween September 2013 and June 2015, 32 premature infants with complications related to HSPDA defined by ultrasound (US) underwent transcatheter closure. The procedure was performed in the catheterization laboratory by venous cannulation without angiography. The position of the occluder was directed by X-ray and US. In particular we looked at procedural details, device size selection, complications, and short and mid-term outcomes.ResultsThirty two premature infants, all of whom had clinical complications related to HSPDA, born at gestational ages ranging between 23.6 and 36 weeks (mean ± standard deviation 28 ± 3 weeks) underwent attempted transcatheter PDA closure using the ADOIIAS. Their mean age and weight at the time of procedure was 25 days (range 8-70 days) and 1373 g (range 680-2480 g), respectively. Ten infants weighed ≤1,000g. All ducts were tubular. The mean PDA and device waist diameters were 3.2 ± 0.6mm (range 2.2-4) and 4.4 ± 0.6 mm, respectively, and the mean PDA and device lengths 5.2 ± 2.0 mm (range 2-10) and 3.4 ± 1.3 mm. Median fluoroscopy and procedural times were 11 min (range 3-24) and 28 min (range 10-90), respectively. Complete closure was achieved in all but one patient. There was no device migration. A left pulmonary artery (LPA) obstruction developed in one patient. Five infants died. Four deaths were related to complications of prematurity and one death in a 680 g infant was related to the procedure.ConclusionsIt is feasible to close HSPDA in relative safety in premature infants who have severe and complex disease. Success requires perfect selection of the occluder and exact positioning by US. © 2017 Wiley Periodicals, Inc.© 2017 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…