• J Pediatr Orthop · Mar 2018

    Observed Length Increases of Magnetically Controlled Growing Rods are Lower Than Programmed.

    • Sarah E Gilday, Mark S Schwartz, Donita I Bylski-Austrow, David L Glos, Lindsay Schultz, Sara O'Hara, Viral V Jain, and Peter F Sturm.
    • Cincinnati Children's Hospital Medical Center, Cincinnati, OH.
    • J Pediatr Orthop. 2018 Mar 1; 38 (3): e133-e137.

    BackgroundMagnetically controlled growing rods (MCGRs) are increasingly used in the treatment of early onset scoliosis (EOS). Few studies have reported whether desired lengthening can reliably be achieved, or if prior spine instrumentation and large tissue depths affect lengthening. In this clinical study of EOS patients, it was hypothesized that increases in rod length would equal programmed increases, patients with prior spine instrumentation would lengthen less than patients without prior surgery, and larger tissue depths would decrease lengthening success.MethodsA retrospective chart review was conducted on EOS patients with single and dual MCGRs placed between April 2014 to September 2015 and distracted at a single institution. Rod distraction was measured at each visit using ultrasound. Differences between programmed and actual distraction for each patient, and between groups with and without prior spine instrumentation, were determined by 2-tailed t tests. Regression and correlation were used to determine the relationship between tissue depth and length increases.ResultsThirty-one patients were included, 18 males, 13 females, age 8.1 (±2.5) years, with major curves measuring 60 (±14.6) degrees at time of MCGR insertion. In the 12 patients with prior instrumentation, time from initial growing rod placement to MCGR insertion was 23.1 (±10.6) months. The number of surgical procedures before MCGR insertion was 2.8 (±2.0). Total length increase relative to the programmed distraction was 86% (±21) (P<0.001). Length increases for patients with and without prior surgery were 87% (±23) and 86% (±19), respectively (P>0.9). Total lengthening was inversely proportional to tissue depth (r=0.38, P<0.01); the decrease in lengthening achieved was 2.1%/mm of tissue depth.ConclusionsIncreases in rod length were 14% lower than the programmed distraction. Prior instrumentation did not impact the amount of rod distraction. Greater distance between the rod and the skin surface negatively affected the magnitude of distraction.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.