• Calcif. Tissue Int. · Aug 2000

    Comparative Study

    Total body and regional bone mineral densitometry (BMD) and soft tissue measurements: correlations of BMD parameter to lumbar spine and hip.

    • H Franck and M Munz.
    • Center of Rheumatology, Oberammergau, Germany.
    • Calcif. Tissue Int. 2000 Aug 1; 67 (2): 111-5.

    AbstractBone loss in men and women seems to differ according to the skeletal regions or particular areas being evaluated. Dual energy X-ray absorptiometry (DXA) is the method of choice for measuring total body and regional bone mineral area density (BMD). The aim of the study was to evaluate the importance of DXA measurements of total body in relation to lumbar spine and hip in different scan beam designs. In 300 patients, ages 43-80 years, lumbar spine, hip, total body and regional bone mineral area density, and soft tissue measurements were performed on all subjects in the supine position on a QDR 2000 using single beam (SB) and fan beam (FB). Short-term precision errors were 0.7% (SB) and 1.2% (FB) for BMD total of the total body and between 1.2% and 8.0% for soft tissue measurements. All mid-term precision errors of BMD total, right and left leg, and pelvis were below 2.0% with SB and FB, whereas precision errors of thoracic and lumbar spine varied depending on the scan mode being applied. In contrast, all mid-term precision errors of soft tissue measurements were greater (2.6-11.0%). All SB values of BMD and soft tissue measurement were significantly higher than FB values, except for BMD values of the head, thoracic spine, and pelvis. Furthermore, BMD total of the total body scan correlated significantly (P < 0. 001) with all subregional parameters with best "r"-values (0.86-0. 92) for the right and left leg in SB and FB design. In addition, there were excellent correlations (r > 0.94, P < 0.001) between the right and left legs (SB and FB) or arms (SB). There were also highly significant correlations between the lumbar spine (or hip) and total body, being best for the subregional thorax. Our data demonstrate short-and mid-term precision errors of BMD with reproducible results for most areas in SB and FB design, whereas soft tissue measurements vary depending on the area being measured. Furthermore, there is a close relationship between BMD values of total body total and subregional parameters and lumbar spine and hip scans, respectively.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,704,841 articles already indexed!

We guarantee your privacy. Your email address will not be shared.