    Spiral imaging artifact reduction: a comparison of two k-trajectory measurement methods.

    • Silke M Lechner, Pekka T Sipilä, Florian Wiesinger, Adam B Kerr, and Mika W Vogel.
    • Advanced Medical Applications Laboratory, GE Global Research Europe, Munich, Germany. silke.lechner@ge.com
    • J Magn Reson Imaging. 2009 Jun 1; 29 (6): 1485-92.

    PurposeTo compare an external sensor-based k-space calibration technique with a routine precalibration method for quantification of method accuracy and reduction of spiral imaging artifacts to obtain improved image quality.Materials And MethodsRecently, magnetic field monitoring (MFM) has been introduced as a new calibration technique of gradient field-related imperfections. External sensors are placed near the observed object to measure magnetic field variations during image acquisition. The measured field data are used to determine the actual k-space trajectory and for image reconstruction to reduce artifacts. In the past, precalibration techniques have been proposed where the k-space trajectory is measured by means of special calibration sequences directly in the object of interest. In this study, MFM is introduced as an effective correction technique for spiral imaging. On the basis of a comparison, whether MFM is as viable as the chosen reference method presented by Duyn et al (J Magn Reson [1998] 132:150-153) is analyzed in terms of detecting imperfections of spatial encoding gradients in order to correct for these in image reconstruction. As this technique is used as a reference method, it is given the acronym Duyn calibration technique (DCT). MFM and DCT are compared and timing delays, k-space offsets, eddy current effects, k-trajectory error propagation, image distortions, and signal-to-noise ratio were determined for different spiral sequences in two different phantoms.ResultsBoth techniques effectively detect k-space offsets and k-trajectory error propagation and correct for general error sources like timing delays. In object border areas, artifacts such as deformations and blurring were dramatically reduced. Within all tested categories, MFM performed as well as DCT. In terms of k-trajectory error propagation and image distortion quantification, MFM was more accurate.ConclusionWe introduce MFM as an effective and accurate correction technique for spiral imaging, where a comparison of MFM and DCT has shown that both techniques are accurate correction techniques for spiral imaging.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.