• Int. J. Radiat. Oncol. Biol. Phys. · Oct 1999

    Dose-volume analysis for quality assurance of interstitial brachytherapy for breast cancer.

    • F A Vicini, L L Kestin, G K Edmundson, D A Jaffray, J W Wong, V R Kini, P Y Chen, and A A Martinez.
    • Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI 48073, USA. fvicini@beaumont.edu
    • Int. J. Radiat. Oncol. Biol. Phys. 1999 Oct 1; 45 (3): 803-10.

    Purpose/ObjectiveThe use of brachytherapy in the management of breast cancer has increased significantly over the past several years. Unfortunately, few techniques have been developed to compare dosimetric quality and target volume coverage concurrently. We present a new method of implant evaluation that incorporates computed tomography-based three-dimensional (3D) dose-volume analysis with traditional measures of brachytherapy quality. Analyses performed in this fashion will be needed to ultimately assist in determining the efficacy of breast implants.Methods And MaterialsSince March of 1993, brachytherapy has been used as the sole radiation modality after lumpectomy in selected protocol patients with early-stage breast cancer treated with breast-conserving therapy. Eight patients treated with high-dose-rate (HDR) brachytherapy who had surgical clips outlining the lumpectomy cavity and underwent computed tomography (CT) scanning after implant placement were selected for this study. For each patient, the postimplant CT dataset was transferred to a 3D treatment planning system. The lumpectomy cavity, target volume (lumpectomy cavity plus a 1-cm margin), and entire breast were outlined on each axial slice. Once all volumes were entered, the programmed HDR brachytherapy source positions and dwell times were imported into the 3D planning system. Using the tools provided by the 3D planning system, the implant dataset was then registered to the visible implant template in the CT dataset. The distribution of the implant dose was analyzed with respect to defined volumes via dose-volume histograms (DVH). Isodose surfaces, the dose homogeneity index, and dosimetric coverage of the defined volumes were calculated and contrasted. All patients received 32 Gy to the entire implanted volume in 8 fractions of 4 Gy over 4 days.ResultsThree-plane implants were used for 7 patients and a two-plane implant for 1 patient. The median number of needles per implant was 16.5 (range 11-18). Despite visual verification by the treating physician that surgical clips (with an appropriate margin) were within the boundaries of the implant needles, the median proportion of the lumpectomy cavity that received the prescribed dose was only 87% (range 73-98%). With respect to the target volume, a median of only 68% (range 56-81%) of this volume received 100% of the prescribed dose. On average, the minimum dose received by at least 90% of the target volume was 22 Gy (range 17.3-26.9), which corresponds to 69% of the prescribed dose.ConclusionPreliminary results using our new technique to evaluate implant quality with CT-based 3D dose-volume analysis appear promising. Dosimetric quality and target volume coverage can be concurrently analyzed, allowing the possibility of evaluating implants prospectively. Considering that target volume coverage may be suboptimal even after radiographically verifying accurate implant placement, techniques similar to this need to be developed to ultimately determine the true efficacy of brachytherapy in the management of breast cancer.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.