• J Magn Reson Imaging · Sep 2007

    Improved bulk myocardial motion suppression for navigator-gated coronary magnetic resonance imaging.

    • Cosima Jahnke, Kay Nehrke, Ingo Paetsch, Bernhard Schnackenburg, Rolf Gebker, Eckart Fleck, and Eike Nagel.
    • Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Berlin, Germany. jahnke@dhzb.de
    • J Magn Reson Imaging. 2007 Sep 1; 26 (3): 780-6.

    PurposeTo evaluate the impact of a new, cross-correlation based method for compensation of respiratory induced motion of the heart using an individually adapted three-dimensional (3D) translation or affine transformation approach.Materials And MethodsA total of 32 patients underwent a routine cardiac MR examination. In each patient, a calibration scan was performed during free-breathing to register breathing-related motion within a 3D ellipsoid registration kernel covering the entire heart. Three navigators were employed for all three spatial dimensions (feet-head, anterior-posterior, and left-right) and the optimal translatory correction factors for each spatial dimension were determined. In addition, the cross-correlations for different motion models (no compensation, fixed 1D-translation, adapted 3D-translation, and affine transformation) were calculated.ResultsThe mean correction factor for the feet-head direction was 0.45 +/- 0.13. Though the mean correction factors for the anterior-posterior and left-right direction were nearly zero (-0.01 +/- 0.08 and 0.02 +/- 0.09, respectively), the correction factors exceeded the amount of 0.1 in 12 (19%) and in 19 patients (30%), respectively. All motion compensation models showed significantly higher cross-correlations when compared to "no compensation" (P < 0.05). In particular, the affine transformation algorithm achieved the highest cross-correlation values (88.3 +/- 5.1%) with a significant increase compared to fixed 1D translation (84.7 +/- 6.5%, P < 0.05).ConclusionA considerable number of patients demonstrated relevant breathing-related movement of the heart in the anterior-posterior or left-right direction in addition to the predominant breathing-related movement in the feet-head direction. Thus, it is recommended to compensate for all three spatial dimensions. The affine transformation algorithm combined with three navigators significantly improved breathing-related cardiac motion compensation when compared to the conventionally applied 1D translation with a fixed correction factor.(c) 2007 Wiley-Liss, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.