• Clin Physiol Funct Imaging · Mar 2012

    The washout rate of a subcutaneous 99mTc-HSA depot in lower extremity lymphoedema.

    • Mads R Jensen, Lene Simonsen, Tonny Karlsmark, and Jens Bülow.
    • Department of Clinical Physiology and Nuclear Medicine, Bispebjerg Hospital, University Hospital of Copenhagen, Copenhagen, Denmark. mjen0221@bbh.regionh.dk
    • Clin Physiol Funct Imaging. 2012 Mar 1; 32 (2): 126-32.

    PurposeLymphoscintigraphy is currently the leading diagnostic modality of lower extremity lymphoedema but has been criticized for being unreliable. Washout rate constants have been investigated and proven to be of diagnostic value in several studies of breast-cancer-related lymphoedema; however, the applicability in lower extremity lymphoedema needs further evaluation. The aim of the study was to verify if washout of (99m) Tc-human serum albumin ((99m) Tc-HSA) is a reliable diagnostic tool in lower extremity lymphoedema.MethodsTwenty healthy volunteers and eight patients (11 legs) with lymphoscintigraphy verified lower extremity lymphoedema participated in the study. A depot consisting of 0.1 ml 10 MBq/ml (99m) Tc-HSA was injected subcutaneously into the dorsum of each foot. The depot washout rate was measured using a portable scintillation detector system and time-activity curves were generated. After 30 min of supine rest and 10 min of standardized ergometric exercise, measurements were recorded for 20 min. Following correction for physical decay of (99m) Tc, the depot washout rate constant was calculated using linear regression analysis. Finally depot half-life was calculated from the washout rate constant.ResultsMedian half-life for healthy volunteers was 9.4 h (range 2.5-28.3 h). Median half-life for lymphoedema patients was 10.7 h (range 1.5-35.1 h). No statistical significant difference could be detected between healthy volunteers and lymphoedema patients (P = 0.78).ConclusionsThe washout rate of a subcutaneous (99m) Tc-HSA depot is not a reliable diagnostic tool in examination of lower extremity lymphoedema. Additional examinations revealed in vivo instability of the utilized (99m) Tc-HSA as the likely reason.© 2011 The Authors. Clinical Physiology and Functional Imaging © 2011 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…