    Totally automatic definition of renal regions of interest from 99mTc-MAG3 renograms: validation in patients with normal kidneys and in patients with suspected renal obstruction.

    • Ernest V Garcia, Russell Folks, Samuel Pak, and Andrew Taylor.
    • Department of Radiology, Emory University School of Medicine, Atlanta, Georgia, USA. Ernest.Garcia@emory.edu
    • Nucl Med Commun. 2010 May 1; 31 (5): 366-74.

    IntroductionAn image-processing algorithm (AUTOROI) has been developed to totally automatically (or with manual assistance) detect whole-kidney contours and generate renal regions of interest (ROI) for the extraction of the quantitative measurements used in the interpretation of Tc-mercaptoacetyltriglycine (Tc-MAG3) renograms.MethodsThe 18-20th min dynamic frames post-MAG3 injection were used to automatically define boxes surrounding each kidney, which were then transposed to an early composite image for interpolative and directional background subtraction. Sobel operator and unsharp masking were applied for edge enhancement, and the resulting image histograms were equalized to better define poorly functioning kidneys. AUTOROI searched radially from the center of mass to define each kidney's ROI coordinates. AUTOROI was validated using MAG3 studies from 79 patients referred for suspected obstruction (79 left, 77 right kidneys) and 19 kidney donors with normal kidney function and no obstruction. Renal ROIs were manually defined by a nuclear medicine technologist with 20+ years of experience (reference standard) and an American Board of Nuclear Medicine certified physician. AUTOROI and physician ROIs were automatically compared with the reference standard to determine the border definition error.ResultsAUTOROI totally automatically detected the renal borders in 89% (172 of 194) of the kidneys from the entire group of 98 patients. The 22 kidneys missed automatically were subsequently detected with the assistance of a single manually placed fiducial point demarcating the liver/kidney boundary. These 22 kidneys were shown to be associated with markedly reduced MAG3 clearance. The mean error of AUTOROI for all 194 kidneys was 6.66+/-3.77 and 7.31+/-4.52 mm for the left and right kidney, respectively. The physician's error was 6.78+/-2.42 and 6.65+/-2.05 mm for the left and right kidney, respectively. This error difference between AUTOROI and the physician was not statistically significant.ConclusionAUTOROI provides an objective and promising approach to automated renal ROI detection.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…