• PM R · Apr 2018

    Comparative Study

    Descriptive Cadaveric Study Comparing the Accuracy of Ultrasound Versus Fluoroscopic Guidance for First Sacral Transforaminal Injections: A Comparison Study.

    • Bradley F Thompson, Matthew J Pingree, Wenchun Qu, Naveen S Murthy, Nirusha Lachman, and Mark Friedrich Hurdle.
    • Department of Physical Medicine and Rehabilitation, Mayo Clinic, 200 1st St SW, Rochester, MN 55905.
    • PM R. 2018 Apr 1; 10 (4): 382-390.

    BackgroundUltrasound is rarely used for guiding lumbosacral epidural steroid injections due to its technical limitations. For example, sonographic imaging lacks the ability to confirm epidural spread and identify vascular uptake. The perceived risk that these limitations pose to human subjects has precluded any large scale clinical trials to date.ObjectiveTo compare the accuracy of ultrasound versus fluoroscopic guidance for first sacral transforaminal epidural injections.DesignCadaveric comparative study using dichotomous outcomes.SettingA fluoroscopy suite and anatomic laboratory at an academic medical center.SubjectsFour unembalmed adult human cadavers with no history of spinal surgery.MethodsEight sites were injected twice by one interventionalist, using fluoroscopic and ultrasound guidance. In the fluoroscopy arm, contrast spread was assessed using computed tomography. In the ultrasound arm, latex spread was assessed using gross anatomic dissection. Any visible evidence of epidural spread constituted a positive result.Main Outcome MeasurementsComparison of the success of obtaining epidural contrast flow was the primary outcome measure. Secondary outcome measures included average duration, rate of intravascular uptake, and quantity of intravascular uptake.ResultsAll injections performed in both the ultrasound arm and the fluoroscopy arm had positive epidural spread. The average duration was 3.03 minutes with fluoroscopy and 4.76 minutes with ultrasound. The rate of intravascular uptake was 37.5% with fluoroscopy and 50% with ultrasound. Within the ultrasound arm, greater intravascular spread and duration variability were recorded.ConclusionAlthough ultrasonography can provide reliable image guidance for cannulating the first sacral foramen in cadavers, it would have limited clinical utility due to its inability to visualize relevant neurovascular structures deep to the osseus roof and exclude intravascular uptake.Level Of EvidenceIV.Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…