• Anesthesia and analgesia · Jan 2009

    Randomized Controlled Trial Comparative Study

    A randomized trial of maximum cephalad sensory blockade with single-shot spinal compared with combined spinal-epidural techniques for cesarean delivery.

    • Damian J Horstman, Edward T Riley, and Brendan Carvalho.
    • Department of Anesthesia, Stanford University School of Medicine, Stanford, California 94305, USA.
    • Anesth. Analg. 2009 Jan 1;108(1):240-5.

    BackgroundPrevious studies have shown more extensive cephalad sensory blockade in women receiving combined spinal-epidural (CSE) anesthesia compared with single-shot spinal (SSS) anesthesia for elective cesarean delivery. It has been postulated that introduction of the epidural needle during CSE disturbs the negative pressure in the epidural space, resulting in relatively greater cerebrospinal fluid (CSF) pressure and increased spread of intrathecal local anesthetic. We tested the hypothesis that CSE results in more extensive cephalad sensory blockade than SSS anesthesia and that loss-of-resistance during initiation of CSE anesthesia increases CSF pressure compared with SSS.MethodsThirty parturients scheduled for elective cesarean delivery were enrolled in this randomized, double-blind study. Patients received either SSS or CSE anesthesia with equal doses of intrathecal anesthetic (hyperbaric bupivacaine 12 mg, fentanyl 10 microg and morphine 200 microg). Before the intrathecal injection, the CSF pressure was measured with a fiberoptic pressure sensor. Maximum cephalad sensory blockade to pinprick, cold and touch was measured. The total dose of phenylephrine required to maintain baseline arterial blood pressure was also recorded.ResultsThere were no significant differences in the median (interquartile range) pinprick sensory block height [T4 (T4-2) vs T3 (T4-1)] or CSF pressures [6 (4-12) vs 9 (8-12) mm Hg] between the SSS and CSE groups. There were no significant correlations between CSF pressure and block height or total dose of phenylephrine.ConclusionThe SSS and CSE techniques inserted in the lateral decubitus position resulted in similar extent of sensory blockade and CSF pressure. These findings suggest that altering the intrathecal dose is not necessary and that any difference in intrathecal pressure associated with initial placement of an epidural needle in the epidural space during CSE anesthesia is clinically inconsequential.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.