• J Bone Joint Surg Am · Jun 2019

    Biomechanics of Biodegradable Subacromial Balloon Spacer for Irreparable Superior Rotator Cuff Tears: Study of a Cadaveric Model.

    • Mario H Lobao, R Bruce Canham, Roshan T Melvani, Joseph A Abboud, Brent G Parks, and Anand M Murthi.
    • Department of Orthopaedic Surgery, MedStar Union Memorial Hospital, Baltimore, Maryland.
    • J Bone Joint Surg Am. 2019 Jun 5; 101 (11): e49.

    BackgroundA subacromial balloon spacer is an option to treat irreparable rotator cuff tears. We hypothesized that the balloon would restore glenohumeral contact pressure, the acromion-humeral interval, and deltoid load to intact values after a simulated irreparable supraspinatus tear in a cadaveric model.MethodsFourteen cadaveric shoulders (mean age at the time of death, 67.9 years) were tested using a custom test frame. In this frame, glenohumeral contact pressure, the acromion-humeral interval, and deltoid load were measured using a digital sensor, a MicroScribe, and a spring scale, respectively. Test conditions included the intact shoulder, a small supraspinatus tear, supraspinatus repair, repair plus balloon, an irreparable supraspinatus tear (rotator cable-insufficient), and an irreparable tear plus balloon. Load was applied in a simulated neutral arm position (balanced) and active shoulder abduction (unbalanced).ResultsWhen the balloon was inflated over the irreparable supraspinatus tear in the balanced condition, glenohumeral contact pressure increased by 122% (p = 0.006) compared with that for the irreparable tear at 0° of abduction and by 94% (p = 0.046) at 60°. In the unbalanced condition, pressure decreased in the irreparable tear condition after the balloon was inflated, restoring pressure to close to that in the intact state. The balloon did not restore glenohumeral contact area to that in the intact shoulder in either the balanced or the unbalanced condition. The irreparable tear displaced the humeral head superiorly in the unbalanced condition, decreasing the acromion-humeral interval. The balloon moved the head inferiorly by a mean (and standard error of the mean) of 6.2 ± 1.3 mm (p < 0.001) at 0° of abduction, 4.4 ± 1.3 mm (p < 0.001) at 30°, and 3.0 ± 0.8 mm (p < 0.001) at 60°. The balloon increased the deltoid load after an irreparable tear by 8.2% (p = 0.022) at 0°, 12.6% (p = 0.002) at 30°, and 11.1% (p = 0.008) at 60°.ConclusionsIn a cadaveric model of an irreparable supraspinatus tear, a balloon spacer restored intact-state glenohumeral contact pressures at most abduction angles, lowered the humeral head, and increased deltoid load at postoperative time 0.Clinical RelevanceThis study supports further investigation of the balloon spacer in comparative clinical studies of surgical options for irreparable rotator cuff tears, with clinically relevant evaluation measures and observation periods.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.