J Vasc Interv Radiol · Apr 2006
Treatment of tracheobronchial obstruction with a polytetrafluoroethylene-covered retrievable expandable nitinol stent.
- Ji Hoon Shin, Ho-Young Song, Gi Young Ko, Tae-Sun Shim, Sang Wee Kim, Young Kwon Cho, Heung-Kyu Ko, Yong Jae Kim, Hyun-Ki Yoon, and Kyu-Bo Sung.
- Department of Radiology and the Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 388-1, Pungnap-2dong, Songpa-gu, Seoul, 138-736, Korea.
- J Vasc Interv Radiol. 2006 Apr 1; 17 (4): 657-63.
PurposeTo evaluate the clinical effectiveness of polytetrafluoroethylene (PTFE)-covered retrievable expandable nitinol stents in tracheobronchial strictures.Materials And MethodsWith fluoroscopic guidance, PTFE-covered retrievable expandable nitinol stents were placed in 15 symptomatic patients with benign (n = 6) or malignant (n = 9) tracheobronchial strictures. Complications and improvement in respiratory status were evaluated. Stents were removed electively 6 months after placement in benign strictures or if complications occurred. Membrane degradation or separation from the wire mesh was evaluated in removed stents.ResultsA total of 17 stents were successfully placed and were well tolerated in all patients. Sputum retention, stent migration, and tissue hyperplasia occurred in 23.5% (n = 4), 17.6% (n = 3), and 17.6% (n = 3) of stents, respectively. A total of 11 stents were successfully removed electively 6 months after placement (n = 4) or when complications occurred (n = 7). All 11 such stents were removed without difficulty with use of standard techniques, antecedent balloon dilation being necessary in two cases as a result of tissue hyperplasia. No removed stent showed signs of membrane degradation, and two removed stents showed signs of membrane separation from the mesh.ConclusionsPTFE-covered retrievable expandable nitinol stents were effective in the treatment of tracheobronchial strictures. Stent removal was easy with use of standard techniques, and no removed stent showed evidence of membrane degradation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.