• JAMA network open · Mar 2020

    Assessment of Radiologist Performance in Breast Cancer Screening Using Digital Breast Tomosynthesis vs Digital Mammography.

    • Brian L Sprague, R Yates Coley, Karla Kerlikowske, Garth H Rauscher, Louise M Henderson, Tracy Onega, Christoph I Lee, Sally D Herschorn, TostesonAnna N AANAThe Dartmouth Institute for Health Policy and Clinical Practice, Lebanon, New Hampshire.Norris Cotton Cancer Center, Geisel School of Medicine at Dartmouth, Lebanon, New Hampshire., and Diana L Miglioretti.
    • Department of Surgery, University of Vermont Cancer Center, University of Vermont, Burlington.
    • JAMA Netw Open. 2020 Mar 2; 3 (3): e201759.

    ImportanceMany US radiologists have screening mammography recall rates above the expert-recommended threshold of 12%. The influence of digital breast tomosynthesis (DBT) on the distribution of radiologist recall rates is uncertain.ObjectiveTo evaluate radiologists' recall and cancer detection rates before and after beginning interpretation of DBT examinations.Design, Setting, And ParticipantsThis cohort study included 198 radiologists from 104 radiology facilities in the Breast Cancer Surveillance Consortium who interpreted 251 384 DBT and 2 000 681 digital mammography (DM) screening examinations from 2009 to 2017, including 126 radiologists (63.6%) who interpreted DBT examinations during the study period and 72 (36.4%) who exclusively interpreted DM examinations (to adjust for secular trends). Data were analyzed from April 2018 to July 2019.ExposuresDigital breast tomosynthesis and DM screening examinations.Main Outcomes And MeasuresRecall rate and cancer detection rate.ResultsA total of 198 radiologists interpreted 2 252 065 DM and DBT examinations (2 000 681 [88.8%] DM examinations; 251 384 [11.2%] DBT examinations; 710 934 patients [31.6%] aged 50-59 years; 1 448 981 [64.3%] non-Hispanic white). Among the 126 radiologists (63.6%) who interpreted DBT examinations, 83 (65.9%) had unadjusted DM recall rates of no more than 12% before using DBT, with a median (interquartile range) recall rate of 10.0% (7.5%-13.0%). On DBT examinations, 96 (76.2%) had an unadjusted recall rate of no more than 12%, with a median (interquartile range) recall rate of 8.8% (6.3%-11.3%). A secular trend in recall rate was observed, with the multivariable-adjusted risk of recall on screening examinations declining by 1.2% (95% CI, 0.9%-1.5%) per year. After adjusting for examination characteristics and secular trends, recall rates were 15% lower on DBT examinations compared with DM examinations interpreted before DBT use (relative risk, 0.85; 95% CI, 0.83-0.87). Adjusted recall rates were significantly lower on DBT examinations compared with DM examinations interpreted before DBT use for 45 radiologists (35.7%) and significantly higher for 18 (14.3%); 63 (50.0%) had no statistically significant change. The unadjusted cancer detection rate on DBT was 5.3 per 1000 examinations (95% CI, 5.0-5.7 per 1000 examinations) compared with 4.7 per 1000 examinations (95% CI, 4.6-4.8 per 1000 examinations) on DM examinations interpreted before DM use (multivariable-adjusted risk ratio, 1.21; 95% CI, 1.11-1.33).Conclusions And RelevanceIn this study, DBT was associated with an overall decrease in recall rate and an increase in cancer detection rate. However, our results indicated that there is wide variability among radiologists, including a subset of radiologists who experienced increased recall rates on DBT examinations. Radiology practices should audit radiologist DBT screening performance and consider additional DBT training for radiologists whose performance does not improve as expected.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…