- Frank G Shellock, David S Fieno, Louise J Thomson, Thomas M Talavage, and Daniel S Berman.
- Department of Radiology, Keck School of Medicine, University of Southern California, Institute for Magnetic Resonance Safety, Education, and Research, Los Angeles, CA, USA. frank.shellock@gte.net
- Am. Heart J. 2006 Feb 1; 151 (2): 436-43.
BackgroundIn vitro testing is used to determine safe parameters before performing magnetic resonance imaging (MRI) on a patient with an implant. Therefore, the objective of this study was to evaluate a cardiac pacemaker using a 1.5-T magnetic resonance (MR) system.MethodsA modern cardiac pacemaker (INSIGNIA I PLUS, Model 1298, and FINELINE II, Model 4471, pacing leads; Guidant Corporation, St Paul, MN) was evaluated for magnetic field interactions at 1.5 T. Magnetic resonance imaging-related heating was assessed using 3 different 1.5-T scanners operating at various levels of radio-frequency power and imaging conditions. Functional aspects of the pacemaker were evaluated immediately before and after MRI (9 different pulse sequences). Artifacts were also characterized.ResultsMagnetic field interactions for the pacemaker were minor. Temperature changes measured in vitro were at levels that are not expected to pose a risk for specific MR conditions (< 4.0 degrees C). The function of the pacemaker was unaffected by MRI. Artifacts were minor for the leads and relatively large for the implantable pulse generator.ConclusionThe findings indicated that this pacemaker exhibited acceptable safety features relative to the use of a 1.5-T MR system. If induced currents do not occur for this device, it may be safe for a patient to undergo MRI by following specific conditions. The results are specific to the pacemaker tested, the MR systems, and conditions used in this evaluation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.