- Michael P Walsh, Coen A Wijdicks, Josh B Parker, Onur Hapa, and Robert F LaPrade.
- Division of Sports Medicine, Department of Orthopaedic Surgery, University of Minnesota, Minneapolis, MN 55454, USA.
- Am J Sports Med. 2009 Jan 1; 37 (1): 160-7.
BackgroundEffective soft tissue graft fixation to the tibial tunnel in all-inside anterior cruciate ligament reconstructions has been reported to be a problem and may lead to retrograde pullout at ultimate load testing.HypothesisA combined retrograde bioabsorbable screw and cortical-cancellous suture button suspension apparatus would gain stiffness from the button and strength from the screw, thus providing for a larger pullout ultimate load, yield load, and stiffness when compared with either fixation alone in an all-inside anterior cruciate ligament reconstruction.Study DesignControlled laboratory study.MethodsEighteen porcine tibias (average bone mineral density of 1.46, measured by dual-energy x-ray absorptiometry scan) and 18 bovine extensor tendon allografts were divided into 3 groups: retrograde bioabsorbable screw fixation, cortical-cancellous suture button suspension apparatus fixation, and combined fixation in the tibia, with 6 specimens per group. They were biomechanically tested with cyclic (500 cycles, 50-250 N, 1 Hz) and load-to-failure (20 mm/min) parameters.ResultsDuring cyclic testing, the retrograde screw-only group had a larger cyclic displacement (2.98 +/- 2.28 mm) than the suture button with retrograde screw combination group (1.40 +/- 0.34 mm). The combination fixation group also produced a higher cyclic stiffness (161.93 +/- 61.81 N/mm) than the retrograde screw-only group (91.59 +/- 43.26 N/mm). In load-to-failure testing, the retrograde screw with suture button combination group withstood significantly higher initial failure forces (873.87 +/- 148.74 N) than the retrograde screw-only (558.44 +/- 126.33 N) and suture button-only (121.76 +/- 40.57 N) groups. Additionally, ultimate loads were also significantly higher for the combination group (1027 +/- 157.11 N) than either the retrograde screw group (679.00 +/- 109.44 N) or the suture button group (161.00 +/- 29.27 N). The retrograde screw with suture button combination group showed significantly higher pullout stiffness (152.50 +/- 46.37 N/mm) than either the retrograde screw-only group (78.31 +/- 12.85 N/mm) or the suture button-only group (25.79 +/- 9.30 N/mm).ConclusionSoft tissue grafts fixed with a combination of a retrograde screw and a suture button were able to withstand higher initial failure and ultimate failure loads and were also stiffer than grafts fixed with either a retrograde screw or a suture button alone.Clinical RelevanceThese findings may prove useful in providing additional stability when using an all-inside technique in a difficult case, or in a patient with poor bone stock, and may also be useful as an alternative to more commonly used tibial tunnel soft tissue fixation techniques.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.