• Magn Reson Med · Mar 2015

    Flip angle-optimized fast dynamic T1 mapping with a 3D gradient echo sequence.

    • Olaf Dietrich, Maximilian Freiermuth, Linus Willerding, Maximilian F Reiser, and Michael Peller.
    • Josef Lissner Laboratory for Biomedical Imaging, Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Germany.
    • Magn Reson Med. 2015 Mar 1; 73 (3): 1158-63.

    PurposeTo analyze the flip angle dependence and to optimize the statistical precision of a fast three-dimensional (3D) T1 mapping technique based on the variable flip angle (VFA) method. The proposed single flip angle (1FA) approach acquires only a single 3D spoiled gradient echo data set for each time point of the dynamical series in combination with a longer baseline measurement.Theory And MethodsThe optimal flip angle for the dynamic series can be calculated as αdyn,opt  = arccos[(2E1  - 1)/(2 - E1 )] (with E1  = exp(-TR /T1 )) by minimizing the statistical error of T1 . T1 maps of a liquid phantom with step-wise increasing concentrations of contrast agent were measured using a saturation recovery (SR) and a VFA/1FA technique with 11 flip angles. The standard deviation of the parameter maps was defined as statistical error of the 1FA measurement.ResultsThe measured statistical error of the 1FA technique as a function of αdyn agrees with the derived theoretical curve. The optimal flip angle increases from about 5° for T1  = 2629 ms to 30° for T1  = 137 ms. The relative deviation between 1FA and SR measurements varies between -2.9 % and +10.3 %. Measurements in vivo confirm the expression for the optimal flip angle.ConclusionThe proposed flip angle-optimized 1FA technique optimizes the precision of T1 values in dynamic phantom measurements.© 2014 Wiley Periodicals, Inc.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…