Comparative Study
[Shortening of the measurement time by 1H-MR turbo spectroscopic imaging of the brain].
- F Träber, W Block, R Lamerichs, E Keller, and H H Schild.
- Radiologische Klinik, Universität Bonn.
- Rofo. 1997 Mar 1; 166 (3): 221-9.
PurposeDevelopment of a new technique for reduction of measurement time in 1H-MR spectroscopic imaging of the brain. Optimisation of the sequence parameters in volunteer and in patient examinations and comparison to the results obtained with conventional 2 D-SI.MethodsExamination of 20 healthy volunteers and 5 patients in a 1.5 T whole-body MR system. In "turbo-spectroscopic imaging" (TSI) sequences, a train of spin-echo signals with different phase encoding is acquired after each 90 degrees excitation. 32 x 32 matrix elements covered a field of view of 20 cm, and additional volume selection was performed by double spin echo excitation. Measurement duration 9 min with acquisition of four phase encoding steps per TR interval, whereas the corresponding 2 D-SI sequence (TR/TE 2000/272 ms) took 30 min.ResultsThe TSI data sets yielded maps of the regional distribution of metabolite concentrations with a quality comparable to the 2 D-SI results. Signal homogeneity and delineation of brain lesions, however, were superior in conventional spectroscopic imaging. The T2 relaxation of the metabolites required a reduced sampling interval for each phase-encoded echo, and hence the frequency resolution of the corresponding TSI spectra was not always sufficient for separating choline and creatine signals.ConclusionWith measurement durations < 10 min the TSI technique allows in clinical studies a combination with single-voxel MRS for accurate quantification and with a diagnostic MRI within a total examination time of less than one hour.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.