• J Magn Reson Imaging · Mar 2005

    An automated algorithm for combining multivoxel MRS data acquired with phased-array coils.

    • Nimrod Maril and Robert E Lenkinski.
    • Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts 02215, USA.
    • J Magn Reson Imaging. 2005 Mar 1; 21 (3): 317-22.

    PurposeTo develop a fully automated algorithm for combining multivoxel magnetic resonance spectroscopy (MRS) data acquired with a phased-array coil.Materials And MethodsThe frequency-domain fitting method of LCModel (Provencher SW, Magn Reson Med 1993;30:672-679) was utilized to analyze the individual data sets. The phase corrections and the metabolite areas were then extracted from the LCModel output files for each individual spectrum. These areas were used to determine the dominant metabolite for each spatial location and to combine the individual spectra in a weighted manner.ResultsThe combination of MRS data acquired from a phantom and the brains of normal volunteers with a four array coil yielded improved signal-to-noise ratio (SNR) in all voxels. The average improvement in SNR of the combined spectrum, as compared with the best of the individual spectra at each spatial location, was 1.4. In the phantom, the predicted SNR improvement of two-fold was achieved at the center of the sample. In the brain, the maximum improvement was 1.8, due to sampling of the ventricles in the center of the sample.ConclusionThe method described in this report provides a means for employing phased-array coils in MRS with the same advantages as those found in MRI.(c) 2005 Wiley-Liss, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…