Investigative radiology · May 2011
Aortic hemodynamics in patients with and without repair of aortic coarctation: in vivo analysis by 4D flow-sensitive magnetic resonance imaging.
- Alex Frydrychowicz, Michael Markl, Daniel Hirtler, Andreas Harloff, Christian Schlensak, Julia Geiger, Brigitte Stiller, and Raoul Arnold.
- Department of Radiology, Medical Physics, University Hospital Freiburg, Germany. frydrychowic@wisc.edu
- Invest Radiol. 2011 May 1; 46 (5): 317-25.
ObjectivesThe purpose of this study was to characterize hemodynamic alterations and flow-derived vessel wall parameters in aortic coarctation (CoA) patients with and without operative repair by time-resolved, 3-dimensional, and 3-directional velocity sensitive, phase-contrast magnetic resonance imaging (4D PC MRI) in comparison with healthy subjects.Methods And MaterialTwenty-four patients, 12.5 ± 6.4 years after CoA repair, 4 patients without treatment for CoA, and 19 healthy subjects were examined. The study was approved by the institutional review board and signature of written informed consent was obtained from the participants. Echocardiography was performed in patients before participation. MRI studies were conducted by applying flow-sensitive 4D phase-contrast MRI at either 1.5 T (n = 5 patients) or 3 T (all 19 healthy subjects, n = 23 patients). Blood flow visualization was used to evaluate overall aortic helicity, presence of pronounced or additional localized helix flow, and vortex development. Quantitative evaluation comprised the calculation of regional time-averaged absolute wall shear stress (WSS(mag)), peak velocities, and oscillatory shear index at 8 locations distributed along the thoracic aorta and additionally at the site of CoA. Inter- and intraobserver variabilities of calculations were determined.ResultsVolunteers and patients demonstrated the same amount of overall aortic helicity. In contrast, the number of additional localized helix flow or vortex formation was significantly increased in patients (25/28 patients vs. 5/19 normal controls, Fisher exact test: P < 0.001). Vortices in the orifices of the supra-aortic branches were detected in 64.3% (18/28) of patients but in only 11.8% (2/19) of controls (P < 0.001). Quantitative analyses revealed a significant increase in overall aortic WSS(mag) (0.44 ± 0.17 N/m(2) in patients vs. 0.27 ± 0.08 N/m(2) in volunteers, P < 0.005) and a decrease in overall oscillatory shear index. Repeated quantitative analysis showed moderate interobserver and low intraobserver variability. Correlation with echocardiography showed good agreement with MRI which tended to underestimate peak velocities (r = 0.76; Bland-Altman analysis, limits of agreement = -0.57-2.16 m/s, mean = 0.79 m/s).ConclusionAlterations in aortic hemodynamics after CoA repair are not limited to the specific region of repair, but can be found in the entire aorta. The presented findings highlight the systemic nature of the disease and the need for a systemic diagnostic approach which can be provided by flow-sensitive 4D PC MRI. Furthermore, valuable additional insights on the hemodynamic consequences of coarctation have been shown that may help understanding secondary complications such as restenosis, aneurysm formation, and arterial hypertension.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.