• J Magn Reson Imaging · Aug 1999

    Comparative Study

    Measurement of cerebral perfusion with dual-echo multi-slice quantitative dynamic susceptibility contrast MRI.

    • E J Vonken, M J van Osch, C J Bakker, and M A Viergever.
    • Department of Radiology, Image Sciences Institute, University Hospital Utrecht, 3584 CX Utrecht, The Netherlands. evertjan@ist.uu.nl
    • J Magn Reson Imaging. 1999 Aug 1; 10 (2): 109-17.

    AbstractQuantitative cerebral perfusion was measured in vivo using dynamic susceptibility contrast magnetic resonance imaging. A dual-echo acquisition was used to eliminate T(1)-enhancement. The arterial input curve was measured in a separate slice in the neck to minimize partial volume effects. Data analysis was performed using a maximum likelihood expectation maximization method to be less sensitive to noise or contrast arrival time differences. From the contrast response curves obtained, the cerebral blood volume (CBV) and flow (CBF) and the timing parameters mean transit time (MTT), time of appearance (TA), and time-to-bolus peak (TBP) were obtained. Adjacent slices were measured to permit discrimination between intra- and inter-subject variance. The group investigated consisted of 41 subjects without cerebral pathology on anatomical MRI. Perfusion parameters for gray (GM) and white matter (WM) were obtained: CBV (GM) = 6.78 +/- 0.99 ml/100 ml, CBV (WM) = 3.78 +/- 0. 96 ml/100 ml, CBF (GM) = 68.7 +/- 21.2 ml/100 ml/min, CBF (WM) = 35. 8 +/- 12.7 ml/100 ml/min, and average GM/WM ratio for CBV (GM/WM) = 1.87 +/- 0.42 and CBF (GM/WM) = 1.99 +/- 0.48. Measured temporal aspects of perfusion were: mean transit time (MTT) (GM) = 6.4 +/- 1. 8 seconds, MTT (WM) = 6.9 +/- 2.3 seconds, time of appearance (TA) (GM) = 1.4 +/- 0.9 seconds, TA (WM) = 2.0 +/- 1.0 seconds, and time-to-bolus peak (TBP) (GM) = 2.4 +/- 1.4 seconds, TBP (WM) = 3.0 +/- 1.5 seconds. The average values were in agreement with those from the literature. Inter- and intra-person variances were estimated using an ANOVA test, and the sources of variance in the parameters, such as image noise, biological variability, and measurement errors of the arterial input curve were found to be of the same order of magnitude. J. Magn. Reson. Imaging 1999;10:109-117.Copyright 1999 Wiley-Liss, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.