-
Int. J. Radiat. Oncol. Biol. Phys. · May 2009
Comparative StudyVolumetric intensity-modulated arc therapy vs. conventional IMRT in head-and-neck cancer: a comparative planning and dosimetric study.
- Wilko F A R Verbakel, Johan P Cuijpers, Daan Hoffmans, Michael Bieker, Ben J Slotman, and Suresh Senan.
- Department of Radiation Oncology, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands.
- Int. J. Radiat. Oncol. Biol. Phys. 2009 May 1; 74 (1): 252-9.
PurposeVolumetric intensity-modulated arc therapy (RA) allows for rapid delivery of highly conformal dose distributions. In this study, planning and dosimetry of RA were compared with conventional intensity-modulated radiation therapy (IMRT) plans of head-and-neck cancer patients.Materials And MethodsComputed tomography scans of 12 patients who had completed IMRT for advanced tumors of the naso-, oro- and hypopharynx were replanned using RA using either one or two arcs. Calculated doses to planning target volume (PTV) and organs at risk (OAR) were compared between IMRT and RA plans. Dose distributions for single arc (n = 8) and double arc (n = 4) plans were verified using film dosimetry in three to five coronal planes using a quality assurance phantom.ResultsRA plans allowed for a mean reduction in number of monitor units (MU) by nearly 60%, relative to seven field sliding window IMRT plans. RA plans achieved similar sparing of all OAR as IMRT. Double arc RA provided the best dose homogeneity to PTV with a lower standard deviation of PTV dose (1.4 Gy), vs. single arc plans (2.0 Gy) and IMRT (1.7 Gy). Film measurements showed good correspondence with calculated doses; the mean gamma value was 0.30 (double arc) and area of the film with a gamma exceeding 1 was 0.82%.ConclusionsRA is a fast, safe, and accurate technique that uses lower MUs than conventional IMRT. Double arc plans provided at least similar sparing of OAR and better PTV dose homogeneity than single arc or IMRT.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.