• Clinical biochemistry · May 2009

    Evaluation of the XE-5000 for the automated analysis of blood cells in cerebrospinal fluid.

    • Klas Boer, Thomas Deufel, and Mike Reinhoefer.
    • Institut fuer Klinische Chemie und Laboratoriumsdiagnostik, Jena, Germany. kboeer@med.uni-jena.de
    • Clin. Biochem. 2009 May 1; 42 (7-8): 684-91.

    ObjectivesCounting of cells in cerebrospinal fluid is an important clinical laboratory test and elevated white blood cell counts in cerebrospinal fluid are frequently seen in CNS disorders. Quantification of red blood cell concentrations in CSF may help to interpret certain diagnostic constellations and may result from subarachnoid haemorrhage, surgical procedures or contamination due to traumatic puncture. Table top analyser XE-5000 (Sysmex, Norderstedt, Germany) offers, beside its use as a haematology analyser, a protocol for the quantification of red and white blood cells in body fluids such as CSF including the differentiation between polymorphonuclear and mononuclear cells. A detection limit of 1 cell/mm(3) would render this device suitable for automated CSF analysis.Design And MethodsWhite blood cell counting was compared between Fuchs-Rosenthal counting chamber and XE-5000 in 273 routinely collected lumbar and ventricular CSF samples. Red blood cell counting was compared between UF-100 and XE-5000. Differentiation was performed on a slide stained after Pappenheim and compared to the differential count of the XE-5000.ResultsLinearity was established between 1 and 10,000 cells/mm(3) for white blood cells and between 1000 and 110(3) particles/mm(3) for red blood cells. Functional sensitivity was established at 20 cells/mm(3) for white blood cell counting and at 1000 particles/mm(3) (lowest reported concentration) for red blood cell counting. When comparing between microscopic and automatic white blood cell counts no statistically significant slope and offset were detected in lumbar CSF samples while a significant slope and offset were detected when comparing ventricular CSF samples. Most patients were classified correctly according to their WBC count (non-pathologic, mildly, moderately, and highly elevated) by both methods although more patients had pathologic white blood cell counts on XE-5000. A significant slope and offset were detected when comparing red blood cell counts between UF-100 and XE-5000.ConclusionsIn summary despite its high imprecision at low white blood cell counts (<20 particles/mm(3)) most patients were classified correctly and therefore XE-5000 is suitable for automated quantification of white blood cells in cerebrospinal fluid in a defined diagnostic setting. This could significantly improve automation in the relatively time- and manual work-intensive field of cerebrospinal fluid diagnostics. However, careful review of plausibility of the results continues to be compulsory.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.