-
Am. J. Clin. Oncol. · Aug 2015
Dosimetric definitions of total lung volumes in calculating parameters predictive for radiation-induced pneumonitis.
- Peyman Kabolizadeh, Ronny Kalash, Mohammed Saiful Huq, Joel S Greenberger, Dwight E Heron, and Sushil Beriwal.
- Department of Radiation Oncology, UPMC Magee-Womens Hospital, University of Pittsburgh Cancer Institute, Pittsburgh, PA.
- Am. J. Clin. Oncol. 2015 Aug 1; 38 (4): 401-4.
ObjectivesThe volume of normal lung receiving 20 Gy (V20) and the mean lung dose (MLD) represent dosimetric parameters used for identifying risk of radiation pneumonitis. However, the total lung volume for dosimetric analysis has been defined differently. Herein we investigate to quantify the dosimetric differences when analysis is based on either definition (ie, excluding planning target volume [PTV] vs. gross tumor volume [GTV] from the total bilateral lung volume).MethodsSixty-one patients with lung cancer who had undergone definitive radiation therapy were retrospectively reviewed. Dosimetric parameters were calculated when excluding GTV or PTV from the total bilateral lung volume.ResultsMedian GTV to PTV margin was 1.3 cm (range, 0.4 to 3.8 cm). Median heterogeneity-corrected RT dose was 74 Gy with the median GTV of 110 mL (range, 13.79 to 665.8 mL) and the median PTV of 346 mL (range, 39.8 to 1258 mL).The MLD, V5, V10, V20, and V30 were all slightly higher and significant when excluding GTV from the total bilateral lung volume compared with similar dosimetric parameters when excluding PTV (P<0.001). Average MLD was 14.8 and 16.7 Gy when excluding PTV and GTV, respectively. Mean V5, V10, V20, and V30 were 49.8%, 38%, 25%, and 18.8% when excluding PTV versus 51.3%, 40%, 28%, and 21.5% when excluding GTV. There were 4 patients with clinical pneumonitis and all had the V20>23% when excluding the PTV versus the V20>27% when excluding the GTV from total bilateral lung volume.ConclusionsA small but significant difference exists between the 2 approaches used to calculate dosimetric variables for lung dose. This difference should be taken into account when comparing dosimetric information between different institutions and when optimizing treatment plans.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.