Eur. J. Appl. Physiol. · Jul 2010
Application of bioreactance for cardiac output assessment during exercise in healthy individuals.
- Adrian Elliott, James H Hull, David Nunan, Djordje G Jakovljevic, David Brodie, and Lesley Ansley.
- School of Life Sciences, Kingston University, Penrhyn Rd, Kingston upon Thames, Surrey, KT1 2EE, UK. adrian.haggett@kingston.ac.uk
- Eur. J. Appl. Physiol. 2010 Jul 1;109(5):945-51.
AbstractIn patients with cardiac failure, bioreactance-based cardiac output (CO) monitoring provides a valid non-invasive method for assessing cardiac performance during exercise. The purpose of this study was to evaluate the efficacy of this technique during strenuous exercise in healthy, trained individuals. Fourteen recreational cyclists, mean (SD) age of 34 (8) years and relative peak oxygen uptake of (VO(2)) 56 (6) ml kg(-1) min(-1), underwent incremental maximal exercise testing, whilst CO was recorded continuously using a novel bioreactance-based device (CO(bio)). The CO(bio) was evaluated against relationship with VO(2), theoretical calculation of arterial-venous oxygen difference (C(a - v) O(2)) and level of agreement with an inert gas rebreathing method (CO(rb)) using a Bland-Altman plot. Bioreactance-based CO measurement was practical and straightforward in application, although there was intermittent loss of electrocardiograph signal at high-intensity exercise. At rest and during exercise, CO(bio) was strongly correlated with VO(2) (r = 0.84; P < 0.001), however, there was evidence of systematic bias with CO(bio) providing lower values than CO(rb); mean bias (limits of agreement) -19% (14.6 to -53%). Likewise, calculated (C(a - v) O(2)) was greater when determined using CO(bio) than CO(rb) (P < 0.001), although both devices provided values in excess of those reported in invasive studies. Bioreactance-based determination of CO provides a pragmatic approach to the continuous assessment of cardiac performance during strenuous exercise in trained individuals. Our findings, however, suggest that further work is needed to refine the key measurement determinants of CO using this device to improve measurement accuracy in this setting.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.