• Radiother Oncol · Jan 2003

    Comparative Study

    Comparative analysis of intensity modulation inverse planning modules of three commercial treatment planning systems applied to head and neck tumour model.

    • Antonella Fogliata, Alessandra Bolsi, and Luca Cozzi.
    • Oncology Institute of Southern Switzerland, Medical Physics Unit, Radiation Oncology Department, Bellinzona, Switzerland. lucozzi@iosi.ch
    • Radiother Oncol. 2003 Jan 1; 66 (1): 29-40.

    Background And PurposeThree commercial treatment planning modules for intensity modulated radiation therapy (IMRT) Inverse Planning, MDS-Nordion Helax-TMS, Varian Cadplan-Helios, and CMS Focus, were compared in an attempt to determine potential application limits or dosimetric differences among various optimisation algorithms.Materials And MethodsA comparative analysis of intensity modulated dose distributions was conducted at planning level on a group of four patients presenting advanced head and neck cancers. In the study, we analysed primarily the static 'step and shoot' multileaf implementation of modulation realisation with some investigation, on the Cadplan-Helios implementation of the 'sliding window', the Varian dynamic approach to IMRT delivery. The whole study was carried out using the inverse planning tools implemented by vendors fully optimising each plan to obtain the best dosimetry given some general plan objectives. To achieve adequate target coverage, optimisation was carried out on Helax-TMS and CMS Focus adding extra margins of 5 or 6mm to the planning target volume (PTV). Beam arrangements were set with five and nine equally spaced fields. The study was conducted with two complexity levels. At the first level, dose-volume constraints were applied only to the target volume and to the spinal cord, while parotid glands were added at the second level. The relative values of dose distributions and dose-volume histograms were compared, together with an estimate of the biological implications in terms of Equivalent Uniform Dose to the target. In the Cadplan-Helios system also the dosimetric implications of the number of intensity levels selected for the discretisation of the fluence matrix were investigated.ResultsWith the application of common planning strategies and the proper consideration of treatment planning system (TPS) specific features (e.g. the PTV margin problem), no substantial differences among the three algorithms were demonstrated at the first level for PTV and spinal cord. At the second level of the study differences were outlined for Helax-TMS, where sub-optimal results were obtained with the 5-field geometry. Mainly due to the differences in optimisation volumes, Cadplan-Helios presented significant better sparing of healthy tissue around the PTV, in terms of mean dose to healthy tissue and Irradiated Volume at 50% dose level. Finally, to achieve dosimetrically acceptable and stable results on target, a minimum of eight intensity levels should be applied for the multileaf collimator (MLC) segmentation, giving an average of 1.5 segments per field and per intensity level.ConclusionsResults obtained for the three IMRT TPS show in first instance that the optimisation algorithms analysed, as well as the conversion from computed fluences to multileaf sequences implemented in the planning systems can produce substantially equivalent dose plans (for target coverage and organs at risk sparing) if planning is performed with common strategies and once a strong understanding of each system feature is achieved. Secondly, a limited number of dose levels (about eight) is adequate at planning level.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…