-
Surg Laparosc Endosc Percutan Tech · Apr 2017
Comparative StudyValidation of a Laparoscopic Ferromagnetic Technology-based Vessel Sealing Device and Comparative Study to Ultrasonic and Bipolar Laparoscopic Devices.
- Jennwood Chen, Curtis R Jensen, Preston K Manwaring, and Robert E Glasgow.
- *Department of Surgery, University of Utah †Domain Surgical Inc., Salt Lake City, UT.
- Surg Laparosc Endosc Percutan Tech. 2017 Apr 1; 27 (2): e12-e17.
IntroductionFerromagnetic heating is a new electrosurgery energy modality that has proven effective in hemostatic tissue dissection as well as sealing and dividing blood vessels and vascularized tissue. The purpose of this study was to evaluate a ferromagnetic-based laparoscopic vessel sealing device with respect to sealing and dividing vessels and vascularized tissue and to compare performance against current vessel sealing technologies.Materials And MethodsA laparoscopic vessel sealing device, Laparoscopic FMsealer (LFM), was studied for efficacy in sealing and dividing blood vessels and comparative studies against predicate ultrasonic, Harmonic Ace+(US), and/or bipolar, LigaSure 5 mm Blunt Tip and/or Maryland (BP), devices in vivo using a swine model and in vitro for comparison of seal burst pressure and reliability. Mann-Whitney and Student t test were used for statistical comparisons.ResultsIn division of 10 cm swine small bowel mesentery in vivo, the laparoscopic FMsealer [12.4±1.8 sec (mean±SD)], was faster compared with US (26.8±2.5 s) and BP (30.0±2.7 s), P<0.05 LFM versus US and BP. Blinded histologic evaluation of 5 mm vessel seals in vivo showed seal lateral thermal spread to be superior in LFM (1678±433 μm) and BP (1796±337 μm) versus US (2032±387 μm), P<0.001. In vitro, seal burst strength and success of sealing 2 to 4 mm arteries were as follows (mean±SD mm Hg, % success burst strength >240 mm Hg): LFM (1079±494 mm Hg, 98.1% success) versus BP (1012±463, 99.0%), P=NS. For 5 to 7 mm arteries: LFM (1098±502 mm Hg, 95.3% success) versus BP (715±440, 91.8%), P<0.001 in burst strength and P=NS in % success. Five 60 kg female swine underwent 21-day survival studies following ligation of vessels ranging from 1 to 7 mm in diameter (n=186 total vessels). Primary seal was successful in 97%, 99% including salvage seals. There was no evidence of postoperative bleeding at sealed vessels at 21-day necropsy.ConclusionThe Laparoscopic FMsealer is an effective tool for sealing and dividing blood vessels and vascularized tissue and compares favorably to current technologies in clinically relevant end points.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.