    Background And AimsPoint of care ultrasound has the potential to become reliable airway assessment tool by accurate prediction of difficult laryngoscopy. We aimed to determine the feasibility of ultrasound in preoperative airway assessment.MethodsThis prospective, observational study was conducted on 200 patients requiring general anaesthesia and tracheal intubation. The thickness of anterior soft tissue neck at the level of hyoid bone (DSHB), epiglottis (DSEM), and Pre-E/E-VC[depth of the pre-epiglottic space (Pre-E)/distance from the epiglottis to the midpoint of the distance between the vocal cords (E-VC)] were measured sonographically. The hyomental distance ratio (HMDR) was measured utilising distances with head in neutral and extended position. The primary outcome was the efficacy of the parameters in predicting difficult laryngoscopy[Cormack Lehane 3,4]. The secondary outcome was to correlate the parameters to CL grading.ResultsUtilising receiver operating curves, cutoff value of HMDR for predicting difficult laryngoscopy was ≤1.0870 with sensitivity of 65%, specificity of 77%. The cutoff value, sensitivity andspecificity for Pre-E/E-VC were ≥1.785, 82.8% and 83.8%., respectively. The cutoff value of DSHB was ≥0.99 with sensitivity of 48% and specificity of 82%. The cutoff, sensitivity and specificity for DSEM were ≥1.615, 89.7%, and 64.8%, respectively. There was moderate positive correlations of DSHB, DSEM, and Pre-E/E-VC (r = 0.551 and 0.701, 0.787: P = 0.00), whereas moderate negative correlation observed with HMDR (r = -.0671: P = 0.00).ConclusionThe strong positive correlation of Pre-E/E-VC, DSEM, and moderate negative correlation of HMDR makes these ultrasound parameters reliable predictors for difficult laryngoscopy.Copyright: © 2019 Indian Journal of Anaesthesia.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.