• Academic radiology · Sep 2004

    Comparative Study

    The effects of geometric distortion correction on motion realignment in fMRI.

    • Mark A Elliott, Eugene E Gualtieri, Justin Hulvershorn, J Daniel Ragland, and Ruben Gur.
    • Department of Radiology, University of Pennsylvania, B1 Stellar Chance Labs, Philadelphia, PA 19104, USA. mark@mail.mmrrcc.upenn.edu
    • Acad Radiol. 2004 Sep 1; 11 (9): 1005-10.

    Rationale And ObjectivesSubject motion is well recognized as a significant impediment to resolution and sensitivity in functional magnetic resonance imaging (fMRI). A parallel confounder to fMRI data quality is geometric image distortion, particularly at high field strengths, due to susceptibility-induced magnetic field inhomogeneity. Consequently, many high-field echo-planar imaging methods incorporate a post-processing distortion correction by acquiring a field map of the sample prior to the fMRI measurement. However, field mapping methods impose a spatial mask on the data, since field information is only obtainable from regions with adequate signal-to-noise ratio (SNR). This masking, when applied to subsequent images in the fMRI time series, can clip the effects of motion, resulting in inaccurate estimation and correction of motion-based changes in the images.Materials And MethodsThe effects of geometric distortion correction on automated realignment (motion correction) of fMRI data are investigated from data acquired at 4 T. The results of image realignment with and without prior application of distortion correction are compared, using the estimated motion parameters and overall image realignment as metrics.ResultsThe application of field-map-based distortion correction prior to image realignment reduces the amount of motion detected by a standard motion correction algorithm. Moreover, motion correction applied before distortion correction is shown to result in superior realignment of motion-correction images.ConclusionIt is preferable to perform motion realignment prior to correcting for geometric distortion.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.