• Health Technol Assess · Mar 2021

    Modelling of hypothetical SARS-CoV-2 point-of-care tests on admission to hospital from A&E: rapid cost-effectiveness analysis.

    • Matt Stevenson, Andrew Metry, and Michael Messenger.
    • School of Health and Related Research (ScHARR), University of Sheffield, Sheffield, UK.
    • Health Technol Assess. 2021 Mar 1; 25 (21): 1-68.

    BackgroundSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the virus that causes coronavirus disease 2019. At the time of writing (October 2020), the number of cases of COVID-19 had been approaching 38 million and more than 1 million deaths were attributable to it. SARS-CoV-2 appears to be highly transmissible and could rapidly spread in hospital wards.ObjectiveThe work undertaken aimed to estimate the clinical effectiveness and cost-effectiveness of viral detection point-of-care tests for detecting SARS-CoV-2 compared with laboratory-based tests. A further objective was to assess occupancy levels in hospital areas, such as waiting bays, before allocation to an appropriate bay.Perspective/SettingThe perspective was that of the UK NHS in 2020. The setting was a hypothetical hospital with an accident and emergency department.MethodsAn individual patient model was constructed that simulated the spread of disease and mortality within the hospital and recorded occupancy levels. Thirty-two strategies involving different hypothetical SARS-CoV-2 tests were modelled. Recently published desirable and acceptable target product profiles for SARS-CoV-2 point-of-care tests were modelled. Incremental analyses were undertaken using both incremental cost-effectiveness ratios and net monetary benefits, and key patient outcomes, such as death and intensive care unit care, caused directly by COVID-19 were recorded.ResultsA SARS-CoV-2 point-of-care test with a desirable target product profile appears to have a relatively small number of infections, a low occupancy level within the waiting bays, and a high net monetary benefit. However, if hospital laboratory testing can produce results in 6 hours, then the benefits of point-of-care tests may be reduced. The acceptable target product profiles performed less well and had lower net monetary benefits than both a laboratory-based test with a 24-hour turnaround time and strategies using data from currently available SARS-CoV-2 point-of-care tests. The desirable and acceptable point-of-care test target product profiles had lower requirement for patients to be in waiting bays before being allocated to an appropriate bay than laboratory-based tests, which may be of high importance in some hospitals. Tests that appeared more cost-effective also had better patient outcomes.LimitationsThere is considerable uncertainty in the values for key parameters within the model, although calibration was undertaken in an attempt to mitigate this. The example hospital simulated will also not match those of decision-makers deciding on the clinical effectiveness and cost-effectiveness of introducing SARS-CoV-2 point-of-care tests. Given these limitations, the results should be taken as indicative rather than definitive, particularly cost-effectiveness results when the relative cost per SARS-CoV-2 point-of-care test is uncertain.ConclusionsShould a SARS-CoV-2 point-of-care test with a desirable target product profile become available, this appears promising, particularly when the reduction on the requirements for waiting bays before allocation to a SARS-CoV-2-infected bay, or a non-SARS-CoV-2-infected bay, is considered. The results produced should be informative to decision-makers who can identify the results most pertinent to their specific circumstances.Future WorkMore accurate results could be obtained when there is more certainty on the diagnostic accuracy of, and the reduction in time to test result associated with, SARS-CoV-2 point-of-care tests, and on the impact of these tests on occupancy of waiting bays and isolation bays. These parameters are currently uncertain.FundingThis report was commissioned by the National Institute for Health Research (NIHR) Evidence Synthesis programme as project number 132154. This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 25, No. 21. See the NIHR Journals Library website for further project information.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.