-
Int. J. Radiat. Oncol. Biol. Phys. · Mar 2007
Comparative StudyRadiation planning comparison for superficial tissue avoidance in radiotherapy for soft tissue sarcoma of the lower extremity.
- Anthony M Griffin, Colleen I Euler, Michael B Sharpe, Peter C Ferguson, Jay S Wunder, Robert S Bell, Peter W M Chung, Charles N Catton, and Brian O'Sullivan.
- Division of Orthopaedic Surgery, University Musculoskeletal Oncology Unit, Mount Sinai Hospital, Toronto, ON, Canada.
- Int. J. Radiat. Oncol. Biol. Phys. 2007 Mar 1; 67 (3): 847-56.
PurposeThree types of preoperative radiotherapy (RT) plans for extremity soft tissue sarcoma were compared to determine the amount of dose reduction possible to the planned surgical skin flaps required for tumor resection and wound closure, without compromising target coverage.Methods And MaterialsTwenty-four untreated patients with large, deep, lower extremity STS treated with preoperative RT and limb salvage surgery had their original conventional treatment plans re-created. The same clinical target volume was used for all three plans. The future surgical skin flaps were created virtually through contouring by the treating surgeon and regarded as an organ at risk. The original, conformal, and intensity-modulated RT (IMRT) plans were created to deliver 50 Gy in 25 fractions to the clinical target volume. Clinical target volume and organ-at-risk dose-volume histograms were calculated and the plans compared for conformality, target coverage, and dose sparing.ResultsThe mean dose to the planned skin flaps was 42.62 Gy (range, 30.24-48.65 Gy) for the original plans compared with 40.12 Gy (range, 24.24-47.26 Gy) for the conformal plans and 26.71 Gy (range, 22.31-31.91 Gy) for the IMRT plans (p = 0.0008). An average of 86.4% (range, 53.2-97.4%) of the planned skin flaps received >or=30 Gy in the original plans compared with 83.4% (range, 36.2-96.2%) in the conformal plans and only 34.0% (range, 22.5-53.3%) in the IMRT plans (p = 0.0001). IMRT improved target conformality compared with the original and conformal plans (1.27, 2.34, and 1.76, respectively, p = 0.0001).ConclusionIn a retrospective review, preoperative IMRT substantially lowered the dose to the future surgical skin flaps, sparing a greater percentage of this structure's volume without compromising target (tumor) coverage.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.