• Respiration · Jan 2004

    Multicenter Study Comparative Study

    Use of studded Polyflex stents in patients with neoplastic obstructions of the central airways.

    • Chris T Bolliger, Albrecht Breitenbuecher, Martin Brutsche, Markus Heitz, and Franz Stanzel.
    • Lung Unit, Department of Internal Medicine, University of Stellenbosch, Tygerberg, Cape Town, South Africa. ctb@sun.ac.za
    • Respiration. 2004 Jan 1; 71 (1): 83-7.

    BackgroundThe Polyflex is a commercially available silastic airway stent with proven efficacy. Due to a smooth outer surface its anchorage in the airway wall is superficial which may lead to stent migration.ObjectiveTo study the performance of an newer version of the Polyflex stent with a studded outer surface, which should improve anchorage.MethodsIn a 5-centre international study the new stent was prospectively tested in symptomatic patients with neoplastic central airway stenosis of more that 50% of normal diameter. Insertion technique, efficacy of stent placement and stent-related complications were recorded before, 1 month and 3 months post stent placement.ResultsUnder general anaesthesia and rigid bronchoscopy 27 stents were inserted in 26 patients, mean age: 62 years (range: 37-83), 16 men. Diagnoses were 18 bronchogenic carcinoma, 4 oesophageal carcinoma, 2 metastases, 1 tracheal carcinoma, and 1 schwannoma. The stents were inserted in the following locations: 10 right main bronchus, 8 left main bronchus, 7 trachea, and 2 tracheo-bronchial. There was significant improvement in all functional parameters assessed from before (A), to 1 month (B) and 3 months (C) after stent placement. The measured values (mean +/- SD) were for the WHO scale: A: 2.7 (0.8), B: 1.5 (0.9), C: 1.6 (1.0); for the Karnofsky scale: A: 44 (19), B: 72 (18), C: 71 (21); for the Dyspnoea Index: A: 3.3 (0.7), B: 1.5 (0.8), C: 1.9 (1.2); for FEV(1): A: 1.2 (0.5), B: 1.9 (0.6), C: 1.5 (0.5), and for FVC: A: 2.1 (0.7), B: 2.8 (0.7), C: 2.5 (1.0). Stent-related complications were 4 reversible stent obstructions by secretions, 1 migration. The observation period was mean 4.3 months (range 2 days to 23 months).ConclusionThe studded Polyflex showed excellent efficacy, was very well tolerated, and had a very low migration rate. It presents an improvement over the older smooth model and can be considered a true alternative to the most widely used silastic stent, the Dumon stent.Copyright 2004 S. Karger AG, Basel

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…