Comparative StudyDosimetric comparison of conventional radiograph- and three-dimensional computed tomography-based planning using dose volume indices for partial breast intraoperative implants.
- S D Sharma, A Budrukkar, R R Upreti, A Munshi, R Jalali, and D D Deshpande.
- Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai, India. shamu_d@yahoo.com
- Clin Oncol (R Coll Radiol). 2008 Feb 1; 20 (1): 46-52.
AimsThe dosimetric outcomes of radiograph- and computed tomography-based plans generated with various optimisation strategies were compared using dose volume indices for partial breast intraoperative implants.Materials And MethodsEighteen patients with early stage breast cancer underwent conventional orthogonal radiograph and computed tomography to generate dosimetric data. Catheter reconstruction and delineation of the lumpectomy cavity, the planning target volume (PTV) and the ipsilateral breast were carried out on computed tomography images. For each patient, geometrically optimised plans (P(xray) and P(CT)) were generated using the active loading length based on the PTV defined from radiographs (PTV(xray)) and computed tomography (PTV(CT)). The plan P(CT) was further optimised graphically and yielded P(graphical). Plans were compared using the coverage index (CI), the external volume index (EI), the dose homogeneity index (DHI), the overdose volume index (OI) and the conformal index (COIN).ResultsThe mean CI of the lumpectomy cavity estimated from P(xray), P(CT) and P(graphical) was 0.80, 0.82 and 0.92, respectively. The corresponding values for PTV(CT) were 0.69, 0.71 and 0.85. P(graphical) showed an increase in CI by 23 and 19% with respect to P(xray) and P(CT) (P<0.001 in all) with a decrease in DHI from 0.81 to 0.71 (P<0.001) and increase in OI from 0.041 to 0.087 (P<0.001). The EI was highest in P(xray) (mean 44 cm(3)) as compared with 25 cm(3) in P(CT) and 30 cm(3) in P(graphical). A significant improvement in COIN was observed in P(graphical) (mean 0.68) compared with P(xray) (0.48) and P(CT) (0.58) (P<0.001).ConclusionsObjective dosimetric evaluation on three-dimensional computed tomography confirms its superiority over conventional two-dimensional radiograph-based planning in terms of a reduction in normal breast irradiated with the prescription dose and improvement in conformity. Interactive graphical optimisation based on the target volume in computed tomography further improves conformity with a reduction in dose homogeneity. The use of dose volume indices allows the comparison of different plans and can be used as a tool to correlate dosimetric with clinical outcome.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.