    Comparison of intensity-modulated tomotherapy with stereotactically guided conformal radiotherapy for brain tumors.

    • V S Khoo, M Oldham, E J Adams, J L Bedford, S Webb, and M Brada.
    • Neuro-oncology Unit, The Institute of Cancer Research and the Royal Marsden NHS Trust, Sutton, Surrey, United Kingdom.
    • Int. J. Radiat. Oncol. Biol. Phys. 1999 Sep 1; 45 (2): 415-25.

    PurposeIntensity-modulated radiotherapy (IMRT) offers the potential to more closely conform dose distributions to the target, and spare organs at risk (OAR). Its clinical value is still being defined. The present study aims to compare IMRT with stereotactically guided conformal radiotherapy (SCRT) for patients with medium size convex-shaped brain tumors.Methods And MaterialsFive patients planned with SCRT were replanned with the IMRT-tomotherapy method using the Peacock system (Nomos Corporation). The planning target volume (PTV) and relevant OAR were assessed, and compared relative to SCRT plans using dose statistics, dose-volume histograms (DVH), and the Radiation Therapy Oncology Group (RTOG) stereotactic radiosurgery criteria.ResultsThe median and mean PTV were 78 cm3 and 85 cm3 respectively (range 62-119 cm3). The differences in PTV doses for the whole group (Peacock-SCRT +/-1 SD) were 2%+/-1.8 (minimum PTV), and 0.1%+/-1.9 (maximum PTV). The PTV homogeneity achieved by Peacock was 12.1%+/-1.7 compared to 13.9%+/-1.3 with SCRT. Using RTOG guidelines, Peacock plans provided acceptable PTV coverage for all 5/5 plans compared to minor coverage deviations in 4/5 SCRT plans; acceptable homogeneity index for both plans (Peacock = 1.1 vs. SCRT = 1.2); and comparable conformity index (1.4 each). As a consequence of the transaxial method of arc delivery, the optic nerves received mean and maximum doses that were 11.1 to 11.6%, and 10.3 to 15.2% higher respectively with Peacock plan. The maximum optic lens, and brainstem dose were 3.1 to 4.8% higher, and 0.6% lower respectively with Peacock plan. However, all doses remained below the tolerance threshold (5 Gy for lens, and 50 Gy for optic nerves) and were clinically acceptable.ConclusionsThe Peacock method provided improved PTV coverage, albeit small, in this group of convex tumors. Although the OAR doses were higher using the Peacock plans, all doses remained within the clinically defined threshold and were clinically acceptable. Further improvements may be expected using other methods of IMRT planning that do not limit the treatment delivery to transaxial arcs. Each IMRT system needs to be individually assessed as the paradigm utilized may provide different outcomes.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…