-
- David Schneider, Paul Apfaltrer, Sonja Sudarski, John W Nance, Holger Haubenreisser, Christian Fink, Stefan O Schoenberg, and Thomas Henzler.
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Centre Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim, Germany.
- Acad Radiol. 2014 Apr 1; 21 (4): 431-6.
Rationale And ObjectivesDual-energy computed tomography (DECT) offers various fields of application, especially in angiography using virtual monoenergetic imaging. The aim of this study was to evaluate objective image quality indices of calculated low-kiloelectron volt monoenergetic DECT angiographic cervical and cerebral data sets compared to virtual 120-kV polyenergetic images.Materials And MethodsForty-one patients (21 men, mean age 58 ± 14) who underwent DECT angiography of the cervical (n = 7) or cerebral vessels (n = 34) were retrospectively included in this study. Data acquired with the 80 and 140 kVp tube using dual-source CT technology were subsequently used to calculate low-kiloelectron volt monoenergetic image data sets ranging from 120 to 40 keV (at 10-keV intervals per patient). Vessel and soft tissue attenuation and image noise were measured in various regions of interest, and contrast-to-noise ratio (CNR) was subsequently calculated. Differences in image attenuation and CNR were compared between the different monoenergetic data sets and virtual 120-kV polyenergetic images.ResultsFor cervical angiography, 60-keV monoenergetic data sets resulted in the greatest improvements in vessel attenuation and CNR compared to virtual 120-kV polyenergetic data sets (+40%, +16%; all P < .01). Also for cerebral vessel assessment, 60-keV monoenergetic data sets provided the greatest improvement in vessel attenuation and CNR (+40%, +9%; all P < .01) compared to virtual 120-kV polyenergetic data sets.Conclusions60-keV monoenergetic image data significantly improve vessel attenuation and CNR of cervical and cerebral DECT angiographic studies. Future studies have to evaluate whether the technique can lead to an increased diagnostic accuracy or should be used for dose reduction of iodinated contrast material.Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.