[Osteosynthesis of tibial valgus osteotomies by goniometric CH-N external fixator].
- N Christodoulou, T h Moussas, C Karaindros, C Poyatzis, and C Vretos.
- Service d'Orthopédie, Hôpital, Général de Karpenissi, Grèce.
- Rev Chir Orthop Reparatrice Appar Mot. 1996 Jan 1; 82 (4): 331-5.
IntroductionThe authors present technique and results of a new external fixator, the < < goniometric > > external fixator CH-N for osteosynthesis of high tibial osteotomy for arthritic varus knee deformity on 86 kness (75 patients).Materials And Methods86 knees in varus deformity with degenerative arthritis of the medial compartment (56 females and 16 males - age 63 +/-8 years) were treated for 5 years (1989-1993) by high tibial osteotomy stabilized by a < < goniometric > > external fixator CH-N.ResultsClinical results were 65,9 per cent excellent, 17, 1 per cent good, 11,8 per cent fair and 5,2 per cent poor 1 year after osteotomy (86 cases analyzed), changing in 60 per cent excellent, 22,3 per cent good, 9, 1 per cent fair and 8,5 per cent at 3 years follow-up (61 cases). Radiological results were: - The preoperative mechanical axis of 13 degrees +/- 5 degrees in varus transformed to 4 degrees +/- 2 degrees in valgus at consolidation and to 2,5 degrees +/- 3 degrees in valgus at one year follow-up. At 3 years follow-up we founded a new loss of correction of 1 degree (mean) in 22 per cent of cases (61 cases). - Subchondral density decreased in 91 per cent of cases (86 cases) one year after and in 82 per cent of cases, 3 years after the osteotomy (61 cases). - In 12 per cent of cases we found a decrease of the overcorrectional angle of the varus deformity 1 year after, and in 22 per cent of cases 3 years after. Two cases needed total knee arthroplasty 4 years after ostcotomy. - Postoperatively, in 86 per cent of cases we did not found increase in both clinical and radiological (pathological) findings of the patellofemoral joint one year after, and in 75 per cent of cases 3 years after.DiscussionThe principle of this special < < goniometri > > external fixator is based on the < < goniometric > > central joint in the frontal plane, this allows to guide the screws during osteotomy in the predesigned position and to control the correction during and after the procedure, in contrary to the others current system either internal or external. Any faulty correction can be modified. With its distal screwing axis, it allows axial dynamization. There are only some but not serious incoveniences due to the application of pins (temporary neuromuscular problems and pin-track infections.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.