• J Shoulder Elbow Surg · Jul 2002

    Randomized Controlled Trial Comparative Study Clinical Trial

    Cemented polyethylene versus uncemented metal-backed glenoid components in total shoulder arthroplasty: a prospective, double-blind, randomized study.

    • Pascal Boileau, Cyril Avidor, Sumant G Krishnan, Gilles Walch, Jean-François Kempf, and Daniel Molé.
    • Department of Orthopaedic Surgery, Hôpital de L'Archet-University of Nice, France. boileau.p@chu-nice.fr
    • J Shoulder Elbow Surg. 2002 Jul 1; 11 (4): 351-9.

    AbstractThirty-nine patients (forty shoulders) with primary osteoarthritis consented to be randomized to receive either a cemented all-polyethylene glenoid component or a cementless metal-backed component at the time of total shoulder arthroplasty. Their mean age was 69 years. Preoperative and postoperative evaluations were completed at 3, 6, 12, 24, and 36 months by history, physical examination, radiographs, and Constant scoring system. The presence of periprosthetic radiolucent lines was significantly greater with polyethylene than with metal-backed glenoids (85% vs 25%, P <.01). Of 20 radiolucent lines, 12 (60%) around polyethylene glenoids were present on immediate postoperative radiographs and 25% were progressive. No significant correlation was found between the presence of radiolucent lines around polyethylene glenoids and functional results (P =.3). By contrast, periprosthetic radiolucent lines around metal-backed glenoids were rare but progressive when present. The incidence of loosening of metal-backed implants (4 cases, 20%) was significantly higher than that observed with polyethylene glenoids (0%, P <.001) and was associated with component shift and severe osteolysis. Metal-backed glenoid loosening significantly correlated with deteriorating functional results and increasing pain (P <.05). Revision surgery was required for 4 patients in the metal-backed group (P =.02), for a subscapularis tear (1 case) and metal-backed glenoid component loosening (3 cases). Computed tomography scan analysis and revision surgery revealed that preoperative posterior humeral subluxation may recur with time despite glenoid reorientation and may cause asymmetric accelerated polyethylene wear, resulting in metal-on-metal contact and severe osteolysis. Reimplantation of a stable cemented glenoid component was possible in 1 case, whereas the cavitary defect was packed with cancellous bone in the 2 other cases. At a minimum of 3 years' follow-up, the results of this study clearly show that (1) the survival rate of cementless, metal-backed glenoid components is inferior to cemented all-polyethylene components and (2) the incidence of radiolucency at the glenoid-cement interface with all-polyethylene components is high and remains a concern. The high rate of loosening, because of the absence of ingrowth and/or the accelerated polyethylene wear, has led us to abandon the use of metal-backed glenoids. Efforts must continue to improve glenoid component design and fixation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.