• Clinical biomechanics · Jun 2006

    Dynamic in vitro measurement of posterior cruciate ligament load and tibiofemoral stress after TKA in dependence on tibiofemoral slope.

    • Sven Ostermeier, Christoph Schlomach, Christof Hurschler, Henning Windhagen, and Christina Stukenborg-Colsman.
    • Orthopaedics Department, Hannover Medical School, MHH, Anna-von-Borries-Str. 1-7, D-30625 Hannover, Germany. sven.ostermeier@annastift.de
    • Clin Biomech (Bristol, Avon). 2006 Jun 1; 21 (5): 525-32.

    BackgroundTo prevent excessive tension on the posterior cruciate ligament, some knee prosthesis-systems offer the option of creating a posterior tibiofemoral slope of the tibial component. The objective of this study was to investigate the effect of the amount of tibiofemoral slope on the posterior cruciate ligament load and tibiofemoral contact stress after total knee arthroplasty under isokinetic in vitro conditions.MethodsTwelve fresh frozen knee specimens were tested in a knee simulator. After implantation of the Interax I.S.A. knee prosthesis-system with a mobile bearing inlay, a bow shaped load transducer was fixed in the medial fibres of the posterior cruciate ligament. A pressure sensitive film was fixed on the femoral inlay surface. The test cycle simulated an isokinetic extension cycle from 120 degrees of flexion to full extension. First, posterior cruciate ligament load and tibiofemoral peak contact stress were measured with the tibial component implanted with a neutral tibial slope and then with 10 degrees posterior slope.FindingsAfter implantation of the tibial component without tibial slope, posterior cruciate ligament load reached a maximum load of 29.5 N (SD 17.1 N) at 97.8 degrees knee flexion. Tibiofemoral contact stress on the medial compartment reached a maximum of 11.9 MPa (SD 2.4 MPa) on the medial compartment and 15.0 MPa (SD 6.1 MPa) on the lateral compartment. With a tibial slope of 10 degrees , posterior cruciate ligament load reached a maximum of 14.5N (SD 4.9N, P = 0.04) at 100.5 degrees knee flexion and tibiofemoral stress increased to a maximum of 13.3 MPa (SD 4.7 MPa, P = 0.38) medial and 17.4 MPa (SD 8.2 MPa, P = 0.22) lateral in knee extension.InterpretationMaximum posterior cruciate ligament load was observed at high knee flexion angles, decreasing to full extension. The implantation of the tibial base plate with 10 degrees dorsal slope reduced posterior cruciate ligament load significantly in knee flexion above 50 degrees and slightly increased tibiofemoral contact stress in knee extension. Therefore a posterior tibial slope prevents an excessive load on the posterior cruciate ligament while having little effect on tibiofemoral stress at high knee flexion angles.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.