• Prehosp Emerg Care · Jan 2016

    Observational Study

    Impact of Building Height and Volume on Cardiac Arrest Response Time.

    • Anders B Conway, Andrew McDavid, Jamie M Emert, Peter J Kudenchuk, Benjamin A Stubbs, Thomas D Rea, Lihua Yin, Michele Olsufka, Andrew M McCoy, and Michael R Sayre.
    • Prehosp Emerg Care. 2016 Jan 1; 20 (2): 212-9.

    AbstractEmergency medical services (EMS) care may be delayed when out-of-hospital cardiac arrest (OHCA) occurs in tall or large buildings. We hypothesized that larger building height and volume were related to a longer curb-to-defibrillator activation interval. We retrospectively evaluated 3,065 EMS responses to OHCA in a large city between 2003-13 that occurred indoors, prior to EMS arrival, and without prior deployment of a defibrillator. The two-tiered EMS system uses automated external defibrillator-equipped basic life support firefighters followed by paramedics dispatched from a single call center. We calculated three time intervals obtained from the computerized dispatch report and time-synchronized defibrillators: initial 911 call to address curb arrival by first unit (call-to-curb), curb arrival to defibrillator power on (curb-to-defib on), and the combined call-to-defib on interval. Building height and surface area were measured with a validated program based on aerial photography. Buildings were categorized by height as short (<25 ft), medium (26-64 ft) and tall (>64 ft). Volume was categorized as small (<60,000 ft(3)), midsize (60,000-1,202,600 ft(3)) and large (>1,202,600 ft(3)). Intervals were compared using the two-tailed Mann-Whitney test. EMS responded to 1,673 OHCA events in short, 1,134 in medium, and 258 in tall buildings. There was a 1.14 minute increase in median curb-to-defib on interval from 1.97 in short to 3.11 minutes in tall buildings (p < 0.01). Taller buildings, however, had a shorter call-to-curb interval (4.73 for short vs 3.96 minutes for tall, p < 0.01), such that the difference in call-to-defib on interval was only 0.27 minutes: 6.87 for short and 7.14 for tall buildings. A similar relationship was observed for small-volume compared to large-volume building: longer curb-to-AED (1.90 vs. 3.01 minutes, p < 0.01), but shorter call-to-curb (4.87 vs. 4.05, p < 0.01); the difference in call-to-defib on was 0.18 minutes. Both taller and larger-volume buildings had longer curb-to-AED intervals but shorter 911 call-to-curb arrival intervals. As a consequence, building height and volume had a modest overall relationship with interval from call to defibrillator application. These results do not support the hypothesis that either taller or larger-volume buildings need cause poorer outcomes in urban environments.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.