• Magn Reson Med · Oct 2018

    Robust SENSE reconstruction of simultaneous multislice EPI with low-rank enhanced coil sensitivity calibration and slice-dependent 2D Nyquist ghost correction.

    • Mengye Lyu, Markus Barth, Victor B Xie, Yilong Liu, Xin Ma, Yanqiu Feng, and Ed X Wu.
    • Laboratory of Biomedical Imaging and Signal Processing, the University of Hong Kong, Hong Kong, SAR, People's Republic of China.
    • Magn Reson Med. 2018 Oct 1; 80 (4): 1376-1390.

    PurposeTo improve simultaneous multislice (SMS) EPI by robust Nyquist ghost correction in both coil sensitivity calibration and SMS reconstruction.MethodsTo derive coil sensitivity and slice-dependent phase difference map between positive- and negative-echo images, single-band EPI reference data are fully sampled with EPI parameters matched to SMS acquisition. First, the reference data are organized into positive- and negative-echo virtual channels where missing data are estimated using low-rank-based simultaneous autocalibrating and k-space estimation (SAKE) at small matrix size. The resulting ghost-free positive- and negative-echo images are combined to generate coil sensitivity maps. Second, full-matrix positive- and negative-echo images are SENSE reconstructed from the reference data. Their phase difference or error map is then calculated. Last, SMS EPI is reconstructed using phase error correction SENSE (PEC-SENSE) that incorporates phase error map into coil sensitivity maps for negative-echo data. The proposed method was evaluated using both experimental data from 7T systems and simulations.ResultsVirtual coil SAKE eliminated Nyquist ghosts in the single-band EPI, yielding high-quality coil sensitivity maps and phase error maps. The subsequent PEC-SENSE robustly reconstructed SMS EPI under various conditions, including presence of in-plane acceleration, with lesser artifacts and higher temporal SNR than slice-dependent 1D linear correction method.ConclusionThe proposed procedure of virtual coil SAKE calibration and PEC-SENSE reconstruction substantially reduces all ghost-related artifacts originating either directly from SMS EPI data or indirectly from EPI-based coil sensitivity maps. It is computationally efficient, and generally applicable to all SMS EPI-based applications.© 2018 International Society for Magnetic Resonance in Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…