• Magn Reson Med · Oct 2019

    Comparison of gradient echo and gradient echo sampling of spin echo sequence for the quantification of the oxygen extraction fraction from a combined quantitative susceptibility mapping and quantitative BOLD (QSM+qBOLD) approach.

    • Simon Hubertus, Sebastian Thomas, Junghun Cho, Shun Zhang, Yi Wang, and Lothar Rudi Schad.
    • Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
    • Magn Reson Med. 2019 Oct 1; 82 (4): 1491-1503.

    PurposeTo compare gradient echo (GRE) and gradient echo sampling of spin echo (GESSE) sequences for the quantification of the oxygen extraction fraction (OEF) from combined quantitative BOLD and quantitative susceptibility mapping (QSM) with regard to accuracy, precision and parameter initialization.MethodsGRE and GESSE data were acquired from 7 healthy volunteers. QSM was applied to the GRE data and used as a regularization for the single-compartment quantitative BOLD fit to the GESSE and GRE data, respectively, to quantify OEF, deoxygenated blood volume (ν), R2 , and non-blood susceptibility (χnb ). Intersubject means within gray and white matter, respectively, were compared between GESSE and GRE (Student's t) and gray-white matter contrast was determined for each sequence separately. A single- and multi-compartment simulation was used to compare reconstruction accuracy.ResultsIntersubject means and SDs for gray and white matter were OEF = 32.4 ± 1.6%, ν = 2.9 ± 0.1%, R2 = 14.2 ± 0.5 Hz, χnb = -43 ± 5 ppb for GESSE and OEF = 43.0 ± 5.4%, ν = 3.5 ± 0.4%, R2 = 14.4 ± 0.7 Hz, χnb = -43 ± 8 ppb for GRE with a significant difference (P < 0.05) for OEF and ν. Gray-white matter contrast was significant (P < 0.05) in all parameters for GESSE but only in ν and R2 for GRE. All parameters reconstructed from GESSE had higher accuracy than from GRE in the single- but not multi-compartment simulation.ConclusionGESSE yields higher parameter accuracy in simulated gray matter but produces unphysiological gray-white matter contrast in OEF in vivo. GRE produces uniform OEF maps in vivo and is more efficient, which could facilitate a clinical implementation, but revealed biases in simulation. The appropriate sequence should be chosen depending on application.© 2019 International Society for Magnetic Resonance in Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.