• JAMA ophthalmology · Aug 2016

    Feasibility of Human Factors Immersive Simulation Training in Ophthalmology: The London Pilot.

    • George M Saleh, James R Wawrzynski, Kamran Saha, Phillip Smith, Declan Flanagan, Melanie Hingorani, Clinton John, and Paul Sullivan.
    • National Institute for Health Research Biomedical Research Centre at University College London Institute of Ophthalmology, Moorfields Eye Hospital, London, England.
    • JAMA Ophthalmol. 2016 Aug 1; 134 (8): 905-11.

    ImportanceHuman factors training can enhance teamworking and reduce error. It is used regularly in certain medical disciplines, but its use has not been established for ophthalmology to our knowledge.ObjectiveTo explore the feasibility of providing immersive simulation human factors training for ophthalmic surgical teams.Design, Setting, And ParticipantsProspective scenario-based simulation and concept description at University College London Hospital and Moorfields Eye Hospital, London, England, from December 12, 2013, to March 13, 2014. At both sites, fully immersive simulated operating theater environments were used, comprising live interactive communication with patients and theater staff, full anesthetic and operating facilities, replicated patient notes, active vital signs, and the ability to contact surgical or anesthetic teams outside of the theater via telephone. Participants were consultant (attending) and trainee ophthalmic surgeons and anesthetists, operating department assistants and practitioners, and ophthalmic nursing staff.Main Outcomes And MeasuresThe following 4 previously validated rating tools for nontechnical skills were applied to a replicated series of scenarios based on actual patient safety incidents at Moorfields Eye Hospital and in the literature: Observational Teamwork Assessment for Surgery (OTAS), Non-Technical Skills Scale (NOTECHS), Anesthetists' Non-Technical Skills (ANTS), and Non-Technical Skills for Surgeons (NOTSS). The Pearson product moment correlation coefficient was calculated for each pair of scoring tools. Intertool and interassessor reliability was established. Interassessor consistency was compared by calculating a normalized standard deviation of scores for each tool across all assessors.ResultsTwenty simulation scenarios, including wrong intraocular lens implantation, wrong eye operation, wrong drug administration, and wrong patient, were provided. The intertool correlations were 0.732 (95% CI, 0.271-0.919; P = .01) for NOTECHS vs ANTS, 0.922 (95% CI, 0.814-0.968; P < .001) for NOTSS vs ANTS, 0.850 (95% CI, 0.475-0.964; P < .001) for OTAS vs ANTS, 0.812 (95% CI, 0.153-0.971; P = .03) for OTAS vs NOTECHS, 0.716 (95% CI, -0.079 to 0.955; P = .07) for OTAS vs NOTSS, and 0.516 (95% CI, -0.020 to 0.822; P = .06) for NOTECHS vs NOTSS. The normalized standard deviations of scores obtained using each tool across all assessors were 0.024 (95% CI, 0.014-0.091) for NOTSS, 0.060 (95% CI, 0.034-0.225) for OTAS, 0.068 (95% CI, 0.041-0.194) for ANTS, and 0.072 (95% CI, 0.043-0.206) for NOTECHS.Conclusions And RelevanceThis study describes the feasibility of a high-fidelity immersive simulation course specifically for ophthalmic surgical teams. The ANTS and NOTSS had the highest intertool and interrater consistency, respectively. Human factors simulation in ophthalmology offers a new method of teaching team members, with the potential to reduce serious ophthalmic patient safety events. Further work will define its usefulness and practical applications.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…