-
- D Blondin, R S Lanzman, C Mathys, D Grotemeyer, A Voiculescu, W Sandmann, L C Rump, U Mödder, and H-J Wittsack.
- Institut für Radiologie, Uniklinikum Düsseldorf, Germany. blondin@med.uni-duesseldorf.de
- Rofo. 2009 Dec 1; 181 (12): 1162-7.
PurposeContrast-enhanced MRI is considered problematic in renal allograft recipients due to the association of gadolinium administration and the development of NSF. Therefore, we assessed the clinical value of mono- and biexponential analysis of diffusion-weighted imaging (DWI).Materials And MethodsA total of 32 patients were divided into four groups: (a) patients with stable function of renal allograft for at least 6 months, (b) patients with acute deterioration of allograft function, patients who recently underwent transplantation (< 14 days) with good (c) or decreased (d) renal function. T 2w ax. and T 1w cor. and a diffusion-weighted sequence with 16 b-values (b = 0 - 750 s/mm (2)) were performed on a 1.5 T scanner (Magnetom Avanto, Siemens Medical Solutions). ROI-based analysis of the renal cortex was analyzed using the software "Table Curve 2D".ResultsMonoexponential analysis showed an ADC (mono) of 1961 +/- 104 1801 +/- 150, 2053 +/- 169 and 1720 +/- 191 10 (-6)mm (2) /sec for patient group a, b, c and d respectively. The difference in ADC (mono) between group (a) and (b) (p < 0.006) and between group (c) and (d) (p < 0.04) was statistically significant. Biexponential analysis revealed a mean perfusion fraction of 0.21, 0.23, 0.32 and 0.24 for group (a), (b), (c) and (d), respectively. Biexponential ADC showed a higher numerical accuracy. There were no statistically significant inter-group differences in diffusion (ADC (D)) and perfusion (ADC (P)).ConclusionUnenhanced evaluation of renal allografts with DWI is feasible. ADC (mono) of renal cortex correlates with renal function. The significance of the higher numerical accuracy of biexponential analysis in clinical settings requires further evaluation in larger-scale studies.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.